Notifications
You must be signed in to change notification settings - Fork 2.1k
/
Copy pathTest_TC_DRYERCTRL_2_1.yaml
126 lines (112 loc) · 3.73 KB
/
Test_TC_DRYERCTRL_2_1.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
# Copyright (c) 2023 Project CHIP Authors
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
name: 3.2.1. [TC-DRYERCTRL-2.1] Optional Dryness attributes with server as DUT
PICS:
- DRYERCTRL.S
config:
nodeId: 0x12344321
cluster: "Laundry Dryer Controls"
endpoint: 1
unsupportedSelectedDrynessLevel:
type: int8u
defaultValue: 4
SupportedDrynessLevel:
type: int8u
defaultValue: 1
tests:
- label: "Step 1: Wait for the commissioned device to be retrieved"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label:
"Step 2: TH reads from the DUT the mandatory attribute:
SupportedDrynessLevels"
PICS: DRYERCTRL.S.A0000
command: "readAttribute"
attribute: "SupportedDrynessLevels"
response:
constraints:
type: list
maxLength: 4
- label:
"Step 3: TH reads from the DUT the mandatory attribute:
SelectedDrynessLevel"
PICS: DRYERCTRL.S.A0001
command: "readAttribute"
attribute: "SelectedDrynessLevel"
response:
constraints:
type: enum8
minValue: 0
maxValue: 3
- label:
"Step 4:TH writes a supported SelectedDrynessLevel attribute that is
within the list of SupportedDrynessLevels"
PICS: DRYERCTRL.S.A0001
command: "writeAttribute"
attribute: "SelectedDrynessLevel"
arguments:
value: SupportedDrynessLevel
- label: "Wait 2 seconds"
cluster: "DelayCommands"
command: "WaitForMs"
arguments:
values:
- name: "ms"
value: 2000
- label:
"Step 5: after a few seconds, TH reads from the DUT the
SelectedDrynessLevel attribute"
PICS: DRYERCTRL.S.A0001
command: "readAttribute"
attribute: "SelectedDrynessLevel"
response:
value: SupportedDrynessLevel
constraints:
type: enum8
- label:
"Step 6: TH writes an unsupported SelectedDrynessLevel attribute that
is not in list of SupportedDrynessLevels to DUT"
PICS: DRYERCTRL.S.A0001
command: "writeAttribute"
attribute: "SelectedDrynessLevel"
arguments:
value: unsupportedSelectedDrynessLevel
response:
error: CONSTRAINT_ERROR
- label: "Step 6: Operate device to set the condition to read only"
verification: |
Manual operation required
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_SKIP_SAMPLE_APP && DRYERCTRL.S.M.ManuallyControlled
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label:
"Step 7: TH writes a supported SelectedDrynessLevel attribute to DUT
while DUT is not in a valid state."
PICS: DRYERCTRL.S.M.ManuallyControlled && DRYERCTRL.S.A0001
command: "writeAttribute"
attribute: "SelectedDrynessLevel"
arguments:
value: SupportedDrynessLevel
response:
error: INVALID_IN_STATE