Interface for ISystem boiler to MQTT

https://travis-ci.org/ngraziano/isystem-to-mqtt.svg?branch=master https://coveralls.io/repos/github/ngraziano/isystem-to-mqtt/badge.svg?branch=master

The poll_isystem_qtt.py poll the boiler and publish value to mqtt host.

Usage

Installation

pip install --upgrade git+https://github.com/ngraziano/isystem-to-mqtt.git

Read all the value from boiler for testing

dump_isystem.py --serial /dev/ttyUSB0 --deviceid 10

Run the mqtt publish daemon

poll_isystem_mqtt.py --user MQTTUSER --password MQTTPASSWORD --interval 60 --log DEBUG  mqtt.server.example.com

Mode Bimaitre (bimaster)

Boiler may be configured in bismaster mode : it send query during 5s and wait query during 5s. If you have incorrect respond from the boiler you can try to add --bimaster flag to the command line to handle bimaster mode.

This mode is not well tested, ti may not work.

Hardware connection

On my system there is two 4 pin mini DIN connectors for the connection (MODBUS RS-485).

For the connection I use an USB to RS485 adapter : USB-RS485-WE-1800-BT. I connected the Data- B Yellow wire on pin 3 (up right with connector in front of you and plastic pin a the bottom) and the Data+ A Orange wire on pin 4 (low right).

MQTT Topic

Available mqtt topic can be found in isystem_to_mqtt/tables.py.

Variable ZONE_TABLE_MODULENS_O define zone to read.

Variable READ_TABLE_MODULENS_O define topic exported to MQTT.

Variable WRITE_TABLE_MODULENS_O define topic subcribed to send data to boiler.

Main topic are:

TOPIC Description
heating/zone-a/temperature Inside temperature
heating/outside/temperature Outsite temperature
heating/zone-a/day-target-temperature Current day mode target temperature
heating/zone-a/day-target-temperature/SET To set day mode target temperature
heating/zone-a/night-target-temperature Currect night mode target temperature
heating/zone-a/night-target-temperature/SET To set night mode target temperature