Semantic Conventions for OS Process Metrics

Status: Experimental

This document describes instruments and attributes for common OS process level metrics in OpenTelemetry. Also consider the general metric semantic conventions when creating instruments not explicitly defined in this document. OS process metrics are not related to the runtime environment of the program, and should take measurements from the operating system. For runtime environment metrics see semantic conventions for runtime environment metrics.

Warning Existing instrumentations and collector that are using v1.21.0 of this document (or prior):

  • SHOULD NOT adopt any breaking changes from document until the system semantic conventions are marked stable. Conventions include, but are not limited to, attributes, metric names, and unit of measure.
  • SHOULD introduce a control mechanism to allow users to opt-in to the new conventions once the migration plan is finalized.

Process Metrics

Metric: process.cpu.time

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.cpu.time Counter s Total CPU seconds broken down by different states. Experimental
Attribute Type Description Examples Requirement Level Stability
process.cpu.state string The CPU state for this data point. A process SHOULD be characterized either by data points with no state labels, or only data points with state labels. system Recommended Experimental

process.cpu.state has the following list of well-known values. If one of them applies, then the respective value MUST be used; otherwise, a custom value MAY be used.

Value Description Stability
system system Experimental
user user Experimental
wait wait Experimental

Metric: process.cpu.utilization

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.cpu.utilization Gauge 1 Difference in process.cpu.time since the last measurement, divided by the elapsed time and number of CPUs available to the process. Experimental
Attribute Type Description Examples Requirement Level Stability
process.cpu.state string The CPU state for this data point. A process SHOULD be characterized either by data points with no state labels, or only data points with state labels. system Recommended Experimental

process.cpu.state has the following list of well-known values. If one of them applies, then the respective value MUST be used; otherwise, a custom value MAY be used.

Value Description Stability
system system Experimental
user user Experimental
wait wait Experimental

Metric: process.memory.usage

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.memory.usage UpDownCounter By The amount of physical memory in use. Experimental

Metric: process.memory.virtual

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.memory.virtual UpDownCounter By The amount of committed virtual memory. Experimental

Metric: process.disk.io

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.disk.io Counter By Disk bytes transferred. Experimental
Attribute Type Description Examples Requirement Level Stability
disk.io.direction string The disk IO operation direction. read Recommended Experimental

disk.io.direction MUST be one of the following:

Value Description Stability
read read Experimental
write write Experimental

Metric: process.network.io

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.network.io Counter By Network bytes transferred. Experimental
Attribute Type Description Examples Requirement Level Stability
network.io.direction string The network IO operation direction. transmit Recommended Experimental

network.io.direction MUST be one of the following:

Value Description Stability
transmit transmit Experimental
receive receive Experimental

Metric: process.thread.count

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.thread.count UpDownCounter {thread} Process threads count. Experimental

Metric: process.open_file_descriptor.count

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.open_file_descriptor.count UpDownCounter {count} Number of file descriptors in use by the process. Experimental

Metric: process.context_switches

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.context_switches Counter {count} Number of times the process has been context switched. Experimental
Attribute Type Description Examples Requirement Level Stability
process.context_switch_type string Specifies whether the context switches for this data point were voluntary or involuntary. voluntary Recommended Experimental

process.context_switch_type has the following list of well-known values. If one of them applies, then the respective value MUST be used; otherwise, a custom value MAY be used.

Value Description Stability
voluntary voluntary Experimental
involuntary involuntary Experimental

Metric: process.paging.faults

This metric is recommended.

Name Instrument Type Unit (UCUM) Description Stability
process.paging.faults Counter {fault} Number of page faults the process has made. Experimental
Attribute Type Description Examples Requirement Level Stability
process.paging.fault_type string The type of page fault for this data point. Type major is for major/hard page faults, and minor is for minor/soft page faults. major Recommended Experimental

process.paging.fault_type has the following list of well-known values. If one of them applies, then the respective value MUST be used; otherwise, a custom value MAY be used.

Value Description Stability
major major Experimental
minor minor Experimental