sunspec-monitor

Monitoring Sunspec compatible Solar Inverters over Modbus TCP. This is collection of Perl scripts to monitor Inverter status and to log production data.

Included tools:

  • sunspec-status

Tested to work with following Inverters:

Manufacturer Model Firmware Version Notes
SolarEdge SE11400 3.1968 often first connection fails, but subsequent connections work
SolarEdge SE11400 3.2180 works ok
SolarEdge SE3500 3.2173 often first connection fails, but subseuqent connetions work

This script should work with any inverter that supports Modbus TCP and Sunspec standard...

Requirements

sunspec-status

This is simple script to query Inverter (and production/consumption meter) status. Script can be used interactively to display inverter status and details. Or alternatively it can be used to log production data into a CSV formatted file.

Syntax

syntax: sunspec-status [options] <host>

Options:
 --port=<port>, -p <port>      Use port (default 502)
 --meter=<meter>, -m <meter>   Query meter (default 1) 
                               (meter = 1..3  or 0 = no meter)
 --timeout=<sec>, -t <sec>     Timeout (default 10)
 --verbose, -v                 Verbose mode

Examples

To query Inverter information and current status -v (or --verbose) option can be used:


# sunspec-status -v myinverter

INVERTER:
             Model: SolarEdge  SE11400
  Firmware version: 3.1968
     Serial Number: 7Dxxxxxx

            Status: ON (MPPT)

 Power Output (AC):         8014 W
  Power Input (DC):         8136 W
        Efficiency:        98.50 %
  Total Production:      148.122 kWh
      Voltage (AC):       239.50 V (59.95 Hz)
      Current (AC):        33.64 A
      Voltage (DC):       360.60 V
      Current (DC):        22.56 A
       Temperature:        53.97 C (heatsink)

METER (#1):
             Model: WattNode RWND-3D-240-MB
            Option: Production
  Firmware version: 25
     Serial Number: 40xxxxx

   Exported Energy:      148.457 kWh
   Imported Energy:        0.012 kWh
        Real Power:         8026 W
    Apparent Power:         8031 VA
      Power Factor:         1.00
      Voltage (AC):       239.90 V (60.00 Hz)
      Current (AC):        33.39 A

To get inverter status information in CSV format simply invoke script withouth --verbose (or --debug) options.

CSV output is in following format:

Columns 1 2 3 4 5 6 7 8 9 10 11
Values status ac_power dc_power total_production ac_voltage ac_current dc_voltage dc_current temperature exported_energy imporoted_energy

Example output:

# sunspec-status myinverter
ON,8007,8128,148275,237.90,33.71,359.90,22.58,54.21,148609,12

To log data every five minutes following cronjob could be used:

*/5 * * * * /usr/local/bin/sunspec-status myinverter >> /var/log/myinverter.csv &