SRS does not support server-side script, but support http-callback, read ServerSide script.
Build SRS with or without http callback, read Build
SRS can call the http callback, for events:
Event | Data | Description |
---|---|---|
on_connect |
{ "action": "on_connect", "client_id": 1985, "ip": "192.168.1.10", "vhost": "video.test.com", "app": "live", "tcUrl": "rtmp://video.test.com/live?key=xxx", "pageUrl": "http://www.test.com/live.html" } |
When client connected at the specified vhost and app. |
on_close |
{ "action": "on_close", "client_id": 1985, "ip": "192.168.1.10", "vhost": "video.test.com", "app": "live" } |
When client close connection, or server disconnect the connection. |
on_publish |
{ "action": "on_publish", "client_id": 1985, "ip": "192.168.1.10", "vhost": "video.test.com", "app": "live", "stream": "livestream" } |
When client publish stream, for example, use flash or FMLE publish stream to server. |
on_unpublish |
{ "action": "on_unpublish", "client_id": 1985, "ip": "192.168.1.10", "vhost": "video.test.com", "app": "live", "stream": "livestream" } |
When client stop publish stream. |
on_play |
{ "action": "on_play", "client_id": 1985, "ip": "192.168.1.10", "vhost": "video.test.com", "app": "live", "stream": "livestream" } |
When client start play stream. |
on_stop |
{ "action": "on_stop", "client_id": 1985, "ip": "192.168.1.10", "vhost": "video.test.com", "app": "live", "stream": "livestream" } |
When client stop play. |
Note:
- Event: When this event occur, callback the specified HTTP url.
- HTTP url: Can be multiple urls, splits by space, SRS will notice all one by one.
- Data: SRS will POST the data to specified HTTP api.
- Return Code: SRS requires the response is an int, indicates the error, 0 is success. SRS will disconnect the connection when response is not 0, or http status is not 200.
For example, when user connect at vhost/app, verify the ip of client:
# the listen ports, split by space.
listen 1935;
vhost __defaultVhost__ {
http_hooks {
# whether the http hooks enalbe.
# default off.
enabled on;
# when client connect to vhost/app, call the hook,
# the request in the POST data string is a object encode by json:
# {
# "action": "on_connect",
# "client_id": 1985,
# "ip": "192.168.1.10", "vhost": "video.test.com", "app": "live",
# "tcUrl": "rtmp://video.test.com/live?key=d2fa801d08e3f90ed1e1670e6e52651a",
# "pageUrl": "http://www.test.com/live.html"
# }
# if valid, the hook must return HTTP code 200(Stauts OK) and response
# an int value specifies the error code(0 corresponding to success):
# 0
# support multiple api hooks, format:
# on_connect http://xxx/api0 http://xxx/api1 http://xxx/apiN
on_connect http://127.0.0.1:8085/api/v1/clients;
}
}
Note: For more information, read conf/full.conf the section hooks.callback.vhost.com
SRS provides a default HTTP callback server, use cherrypy.
To start it: python research/api-server/server.py 8085
[winlin@dev6 srs]$ python research/api-server/server.py 8085
[2014-02-27 09:42:25][trace] api server listen at port: 8085, static_dir: /home/winlin/git/simple-rtmp-server/trunk/research/api-server/static-dir
[2014-02-27 09:42:25][trace] start cherrypy server
[27/Feb/2014:09:42:25] ENGINE Listening for SIGHUP.
[27/Feb/2014:09:42:25] ENGINE Listening for SIGTERM.
[27/Feb/2014:09:42:25] ENGINE Listening for SIGUSR1.
[27/Feb/2014:09:42:25] ENGINE Bus STARTING
[27/Feb/2014:09:42:25] ENGINE Started monitor thread '_TimeoutMonitor'.
[27/Feb/2014:09:42:25] ENGINE Started monitor thread 'Autoreloader'.
[27/Feb/2014:09:42:25] ENGINE Serving on 0.0.0.0:8085
[27/Feb/2014:09:42:25] ENGINE Bus STARTED
Publish stream to SRS, SRS will call the http callback:
[2014-02-27 09:41:33][trace] post to clients, req={"action":"on_connect","client_id":4,"ip":"192.168.1.179","vhost":"__defaultVhost__","app":"live","pageUrl":""}
[2014-02-27 09:41:33][trace] srs on_connect: client id=4, ip=192.168.1.179, vhost=__defaultVhost__, app=live, pageUrl=
127.0.0.1 - - [27/Feb/2014:09:41:33] "POST /api/v1/clients HTTP/1.1" 200 1 "" "srs(simple rtmp server)0.9.2"
Play stream on SRS, SRS will call the http callback:
[2014-02-27 09:41:50][trace] post to clients, req={"action":"on_connect","client_id":5,"ip":"192.168.1.179","vhost":"__defaultVhost__","app":"live","pageUrl":"http://dev.chnvideo.com:3080/players/rtmp/"}
[2014-02-27 09:41:50][trace] srs on_connect: client id=5, ip=192.168.1.179, vhost=__defaultVhost__, app=live, pageUrl=http://dev.chnvideo.com:3080/players/rtmp/
127.0.0.1 - - [27/Feb/2014:09:41:50] "POST /api/v1/clients HTTP/1.1" 200 1 "" "srs(simple rtmp server)0.9.2"