Notifications
You must be signed in to change notification settings - Fork 0
/
ideAlarmModule.lua
735 lines (651 loc) · 26.1 KB
/
ideAlarmModule.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
--[[
ideAlarm.lua
Please read: https://github.com/allan-gam/ideAlarm/wiki
Copyright (C) 2017 BakSeeDaa
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses
--]]
local config = require "ideAlarmConfig"
local custom = require "ideAlarmHelpers"
local scriptVersion = '2.1.1'
local ideAlarm = {}
-- Possible Zone statuses
local ZS_NORMAL = 'Normal'
ideAlarm.ZS_NORMAL = ZS_NORMAL
local ZS_ARMING = 'Arming'
ideAlarm.ZS_ARMING = ZS_ARMING
local ZS_ALERT = 'Alert'
ideAlarm.ZS_ALERT = ZS_ALERT
local ZS_ERROR = 'Error'
ideAlarm.ERROR = ZS_ERROR
local ZS_TRIPPED = 'Tripped'
ideAlarm.TRIPPED = ZS_TRIPPED
local ZS_TIMED_OUT = 'Timed out'
ideAlarm.ZS_TIMED_OUT = ZS_TIMED_OUT
local SECURITY_PANEL_NAME = config.SECURITY_PANEL_NAME or 'Security Panel'
local SENSOR_CLASS_A = 'a' -- Sensor active in both arming modes. E.g. "Armed Home" and "Armed Away".
ideAlarm.SENSOR_CLASS_A = SENSOR_CLASS_A
local SENSOR_CLASS_B = 'b' -- Sensor active in arming mode "Armed Away" only.
ideAlarm.SENSOR_CLASS_B = SENSOR_CLASS_B
-- BELOW ARE 2 TEMPORARY FUNCTIONS THAT WILL BE OBSOLETE WHEN/IF DZVENTS WILL SUPPORT afterSec(seconds) for text devices.
local function jsonAPI(domoticz, apiCall, delay)
delay = delay or 0
local url = domoticz.settings['Domoticz url']..'/json.htm?'..apiCall
if delay == 0 then
domoticz.openURL(url)
else
os.execute('(sleep '..delay..';curl -s "'..url..'" > /dev/null)&')
end
end
-- We need this function because there is no delay option for updateText!
local function setTextDevice(domoticz, idx, sValue, delay)
delay = delay or 0
if delay == 0 then
domoticz.devices(idx).updateText(sValue)
else
jsonAPI(domoticz, 'type=command¶m=udevice&idx='..idx.."&nvalue=0&svalue="..domoticz.urlEncode(sValue), delay)
end
end
-- END TEMPORARY FUNCTIONS
local function callIfDefined(f)
return function(...)
local error, result = pcall(custom.helpers[f], ...)
if error then -- f exists and is callable
return result
end
end
end
--- Initialize the alarm zones table with config values and some additional functions
local function initAlarmZones()
local zones = {}
for i, alarmZone in ipairs(config.ALARM_ZONES) do
alarmZone.zoneNumber = i
alarmZone.armingMode =
--- Gets the arming mode for the zone
-- @param domoticz The Domoticz object
-- @return String. One of domoticz.SECURITY_DISARMED, domoticz.SECURITY_ARMEDAWAY
-- and domoticz.SECURITY_ARMEDHOME
function(domoticz)
return(domoticz.devices(alarmZone.armingModeTextDevID).state)
end
alarmZone.status =
--- Gets the alarm zone's status
-- @param domoticz The Domoticz object
-- @return String. One of alarm.ZS_NORMAL, alarm.ZS_ARMING, alarm.ZS_ALERT, alarm.ERROR,
-- alarm.ZS_TRIPPED or alarm.ZS_TIMED_OUT
function(domoticz)
return(domoticz.devices(alarmZone.statusTextDevID).state)
end
alarmZone.isArmed =
--- Returns true if the zone is armed
-- @param domoticz The Domoticz object
-- @return Boolean
function(domoticz)
return(alarmZone.armingMode(domoticz) ~= domoticz.SECURITY_DISARMED)
end
alarmZone.isArmedHome =
--- Returns true if the zone is armed home
-- @param domoticz The Domoticz object
-- @return Boolean
function(domoticz)
return(alarmZone.armingMode(domoticz) == domoticz.SECURITY_ARMEDHOME)
end
alarmZone.isArmedAway =
--- Returns true if the zone is armed away
-- @param domoticz The Domoticz object
-- @return Boolean
function (domoticz)
return(alarmZone.armingMode(domoticz) == domoticz.SECURITY_ARMEDAWAY)
end
alarmZone.trippedSensors =
--- Gets all tripped sensor devices for the zone
-- @param domoticz The Domoticz object
-- @param mins Integer 0-9999 Number of minutes that the sensor must have been updated within.
-- A 0 value will return sensor devices who are currently tripped.
-- @param armingMode String One of domoticz.SECURITY_ARMEDAWAY, domoticz.SECURITY_ARMEDHOME or domoticz.SECURITY_DISARMED
-- A sensor is regarded to be tripped only in the context of an arming mode. Defaults to the zones current arming mode.
-- @param isArming Boolean. In an arming scenario we don't want to include sensors that are set not to warn when arming.
-- @return Table with tripped Domoricz devices
function(domoticz, mins, armingMode, isArming)
mins = mins or 1
armingMode = armingMode or alarmZone.armingMode(domoticz)
isArming = isArming or false
local trippedSensors = {}
if armingMode == domoticz.SECURITY_DISARMED then return trippedSensors end
-- Get a list of all open and active sensors for this zone
for sensorName, sensorConfig in pairs(alarmZone.sensors) do
local sensor = domoticz.devices(sensorName)
if ((mins > 0 and sensor.lastUpdate.minutesAgo <= mins)
or (mins == 0 and sensor.active)) then
local includeSensor = (type(sensorConfig.enabled) == 'function') and sensorConfig.enabled(domoticz) or sensorConfig.enabled
if includeSensor and isArming then includeSensor = sensorConfig.armWarn end
if includeSensor then
includeSensor = (armingMode == domoticz.SECURITY_ARMEDAWAY)
or (armingMode == domoticz.SECURITY_ARMEDHOME and sensorConfig.class ~= SENSOR_CLASS_B)
end
if includeSensor then
table.insert(trippedSensors, sensor)
end
end
end
return trippedSensors
end
alarmZone._updateZoneStatus =
---Function to set the alarm zones status
-- @param domoticz The Domoticz object
-- @param newStatus Text (Optional) The new status to set.
-- @param delay Integer (Optional) Delay in seconds.
-- One of alarm.ZS_NORMAL, alarm.ZS_ARMING, alarm.ZS_ALERT, alarm.ERROR,
-- alarm.ZS_TRIPPED or alarm.ZS_TIMED_OUT. Defaults to alarm.ZS_NORMAL
-- @return Nil
function(domoticz, newStatus, delay)
newStatus = newStatus or ZS_NORMAL
delay = delay or 0
if (newStatus ~= ZS_NORMAL)
and (newStatus ~= ZS_ARMING)
and (newStatus ~= ZS_ALERT)
and (newStatus ~= ZS_ERROR)
and (newStatus ~= ZS_TRIPPED)
and (newStatus ~= ZS_TIMED_OUT) then
domoticz.log('An attempt has been made to set an invalid zone status for zone: '
..alarmZone.name, domoticz.LOG_ERROR)
newStatus = ZS_ERROR
delay = 0
end
if alarmZone.status(domoticz) ~= newStatus then
setTextDevice(domoticz, alarmZone.statusTextDevID, newStatus, delay) -- This will trigger this script again
domoticz.log(alarmZone.name..' new status: '..newStatus
..(delay>0 and ' with a delay of '..delay..' seconds' or ' immediately'), domoticz.LOG_INFO)
end
end
alarmZone.disArmZone =
--- Disarms the zone unless it's already disarmed.
-- @param domoticz The Domoticz object
-- @return Nil
function(domoticz)
if alarmZone.armingMode(domoticz) ~= domoticz.SECURITY_DISARMED then
domoticz.devices(alarmZone.armingModeTextDevID).updateText(domoticz.SECURITY_DISARMED)
end
end
alarmZone.armZone =
--- Arms a zone to the given arming mode after an optional delay.
-- Arming a zone also resets it's status
-- @param domoticz The Domoticz object
-- @param z integer/string/table (Optional) The zone to look up.
-- @param armingMode String. The new arming mode to set.
-- Should be one of domoticz.SECURITY_ARMEDAWAY and domoticz.SECURITY_ARMEDHOME
-- @param delay Integer. (Optional) Number of seconds to delay the arming action. Defaults to the
-- zone objects defined exit delay.
-- @return Nil
function(domoticz, armingMode, delay)
delay = delay or (armingMode == domoticz.SECURITY_ARMEDAWAY and alarmZone.exitDelay or 0)
armingMode = armingMode or domoticz.SECURITY_ARMEDAWAY
if (armingMode ~= domoticz.SECURITY_ARMEDAWAY)
and (armingMode ~= domoticz.SECURITY_ARMEDHOME) then
domoticz.log('An attempt has been made to set an invalid arming mode for zone: '
..alarmZone.name, domoticz.LOG_ERROR)
return
end
if alarmZone.armingMode(domoticz) ~= armingMode then
local isArming = true
local trippedSensors = alarmZone.trippedSensors(domoticz, 0, armingMode, isArming)
if (#trippedSensors > 0) then
callIfDefined('alarmZoneArmingWithTrippedSensors')(domoticz, alarmZone, armingMode)
if not alarmZone.canArmWithTrippedSensors then
local msg = ''
for _, sensor in ipairs(trippedSensors) do
if msg ~= '' then msg = msg..' and ' end
msg = msg..sensor.name
end
domoticz.log('An arming attempt has been made with tripped sensor(s) in zone: '
..alarmZone.name..'. Tripped sensor(s): '..msg..'.', domoticz.LOG_ERROR)
alarmZone._updateZoneStatus(domoticz, ZS_ERROR)
return
end
end
if delay > 0 then
alarmZone._updateZoneStatus(domoticz, ZS_ARMING)
end
domoticz.log('Arming zone '..alarmZone.name..
' to '..armingMode..(delay>0 and ' with a delay of '..delay..' seconds' or ' immediately'), domoticz.LOG_INFO)
setTextDevice(domoticz, alarmZone.armingModeTextDevID, armingMode, delay)
end
end
alarmZone.toggleArmingMode =
---Function to toggle the zones arming mode between 'Disarmed' and armType
function(domoticz, armingMode)
armingMode = armingMode or domoticz.SECURITY_DISARMED
local newArmingMode
newArmingMode = (alarmZone.armingMode(domoticz) ~= domoticz.SECURITY_DISARMED and domoticz.SECURITY_DISARMED or armingMode)
if newArmingMode == domoticz.SECURITY_DISARMED then
alarmZone.disArmZone(domoticz)
else
alarmZone.armZone(domoticz, newArmingMode)
end
end
alarmZone.sensorConfig =
--- Looks up and returns the sensor configuration object by given sensor name.
-- Generates an error if a sensor can not be found.
-- @param sensorName String. The sensor to look up.
-- @return The sensor object table
function(sName)
for sensorName, sensorConf in pairs(alarmZone.sensors) do
if sensorName == sName then return sensorConf end
end
print('Error: Can\'t find a sensor with name: \''..sName..'\' defined in '..alarmZone.name..'.')
end
table.insert(zones, alarmZone)
end
return zones
end
--- The alarm zones table
local alarmZones = initAlarmZones()
--- Looks up the zone object for a zone given by name or index.
-- If a zone object is given it will just return it.
-- Generates an error if a zone given by name can not be found.
-- @param z (integer/string/table (Optional) The zone to look up.
-- If not given, the ideAlarm main zone will be used.
-- @return The Zone table
function ideAlarm.zones(z)
local function mainZoneIndex()
for index, z in ipairs(alarmZones) do
if z.mainZone then return index end
end
return(nil)
end
z = z or mainZoneIndex()
if type(z) == 'number' then
return(alarmZones[z])
elseif type(z) == 'string' then
for _, zone in ipairs(alarmZones) do
if zone.name == z then return zone end
end
print('Error: Can\'t find an alarm zone with name: \''..z..'\' in the configuration.')
elseif type(z) == 'table' then
return(z)
end
end
local function toggleSirens(domoticz, device, alertingZones)
local allAlertDevices = {}
for _, alarmZone in ipairs(alarmZones) do
for _, alertDevice in ipairs(alarmZone.alertDevices) do
allAlertDevices[alertDevice] = 'Off'
end
end
for _, zoneNumber in ipairs(alertingZones) do
local alarmZone = ideAlarm.zones(zoneNumber)
domoticz.log('Turning on noise for zone '..alarmZone.name, domoticz.LOG_FORCE)
for _, alertDevice in ipairs(alarmZone.alertDevices) do
if not config.ALARM_TEST_MODE then allAlertDevices[alertDevice] = 'On' end
end
end
for alertDevice, newState in pairs(allAlertDevices) do
if (domoticz.devices(alertDevice) ~= nil)
and domoticz.devices(alertDevice).state ~= newState then
domoticz.devices(alertDevice).toggleSwitch().silent()
if newState == 'On' and config.ALARM_ALERT_MAX_SECONDS > 0 then
domoticz.devices(alertDevice).switchOff().afterSec(config.ALARM_ALERT_MAX_SECONDS).silent()
end
end
end
end
local function onToggleButton(domoticz, device)
-- Checking if the toggle buttons have been pressed
for _, alarmZone in ipairs(alarmZones) do
if device.active and (device.name == alarmZone.armAwayToggleBtn or device.name == alarmZone.armHomeToggleBtn) then
local armType
if device.name == alarmZone.armAwayToggleBtn then
armType = domoticz.SECURITY_ARMEDAWAY
else
armType = domoticz.SECURITY_ARMEDHOME
end
domoticz.log(armType.. ' Alarm mode toggle button for zone "'..alarmZone.name..'" was pushed.', domoticz.LOG_INFO)
alarmZone.toggleArmingMode(domoticz, armType)
end
end
end
local function onStatusChange(domoticz, device)
local alertingZones = {}
-- Loop through the Zones
-- Check if any alarm zones status has changed
for i, alarmZone in ipairs(alarmZones) do
-- Deal with alarm status changes
if device.id == alarmZone.statusTextDevID then
domoticz.log('Deal with alarm status changes '.. 'for zone '..alarmZone.name, domoticz.LOG_DEBUG)
if alarmZone.status(domoticz) == ZS_NORMAL then
callIfDefined('alarmZoneNormal')(domoticz, alarmZone)
elseif alarmZone.status(domoticz) == ZS_ARMING then
callIfDefined('alarmZoneArming')(domoticz, alarmZone)
elseif alarmZone.status(domoticz) == ZS_ALERT then
callIfDefined('alarmZoneAlert')(domoticz, alarmZone, config.ALARM_TEST_MODE)
table.insert(alertingZones, i)
elseif alarmZone.status(domoticz) == ZS_ERROR then
callIfDefined('alarmZoneError')(domoticz, alarmZone)
elseif alarmZone.status(domoticz) == ZS_TRIPPED then
callIfDefined('alarmZoneTripped')(domoticz, alarmZone)
elseif alarmZone.status(domoticz) == ZS_TIMED_OUT then
if alarmZone.armingMode(domoticz) ~= domoticz.SECURITY_DISARMED then
-- A sensor was tripped, delay time has passed and the zone is still armed so ...
alarmZone._updateZoneStatus(domoticz, ZS_ALERT)
else
domoticz.log('No need for any noise, the zone is obviously disarmed now.', domoticz.LOG_INFO)
alarmZone._updateZoneStatus(domoticz, ZS_NORMAL)
end
end
end
end
toggleSirens(domoticz, device, alertingZones)
end
local function onArmingModeChange(domoticz, device)
-- Loop through the Zones
-- Check if any alarm zones arming mode changed
local zonesToSyncCheck = 0
for _, alarmZone in ipairs(alarmZones) do
-- Deal with arming mode changes
-- E.g. the text device text for arming mode has changed
if (device.id == alarmZone.armingModeTextDevID) then
alarmZone._updateZoneStatus(domoticz, ZS_NORMAL) -- Always set to normal when arming mode changes
callIfDefined('alarmArmingModeChanged')(domoticz, alarmZone)
local armingMode = alarmZone.armingMode(domoticz)
if alarmZone.syncWithDomoSec then
zonesToSyncCheck = zonesToSyncCheck + 1
if zonesToSyncCheck > 1 then
domoticz.log('Configuration file error. Only a single zone can be set up to synchronize with the Domoticz\'s security panel.', domoticz.LOG_ERROR)
return
end
if armingMode ~= domoticz.security then
domoticz.log('Syncing Domoticz\'s built in Security Panel with the zone '..alarmZone.name..'\'s arming status', domoticz.LOG_INFO)
if armingMode == domoticz.SECURITY_DISARMED then
domoticz.devices(SECURITY_PANEL_NAME).disarm()
elseif armingMode == domoticz.SECURITY_ARMEDHOME then
domoticz.devices(SECURITY_PANEL_NAME).armHome()
elseif armingMode == domoticz.SECURITY_ARMEDAWAY then
domoticz.devices(SECURITY_PANEL_NAME).armAway()
end
end
end
end
end
end
local function onSensorChange(domoticz, device)
-- A sensor was tripped.
for i, alarmZone in ipairs(alarmZones) do
for sensorName, sensorConfig in pairs(alarmZone.sensors) do
if sensorName == device.name then
local isEnabled
if type(sensorConfig.enabled) == 'function' then
isEnabled = sensorConfig.enabled(domoticz)
else
isEnabled = sensorConfig.enabled
end
if isEnabled
and (alarmZone.armingMode(domoticz) == domoticz.SECURITY_ARMEDAWAY or
(alarmZone.armingMode(domoticz) == domoticz.SECURITY_ARMEDHOME and sensorConfig.class == SENSOR_CLASS_A)) then
domoticz.log(sensorName..' in zone '..alarmZone.name..' was tripped', domoticz.LOG_INFO)
local alarmStatus = domoticz.devices(alarmZone.statusTextDevID).state
if alarmStatus ~= ZS_TRIPPED and alarmStatus ~= ZS_TIMED_OUT and alarmStatus ~= ZS_ALERT then
if (alarmZone.entryDelay > 0) then
alarmZone._updateZoneStatus(domoticz, ZS_TRIPPED) -- Skip ZS_TRIPPED status if 0 secs entry delay
end
alarmZone._updateZoneStatus(domoticz, ZS_TIMED_OUT, alarmZone.entryDelay)
end
end
break -- Let this sensor trigger only once in this zone
end
end
end
end
local function onSecurityChange(domoticz, triggerInfo)
-- Domoticz built in Security state has changed, shall we sync the new arming mode to any zone?
local zonesToSyncCheck = 0
for i, alarmZone in ipairs(alarmZones) do
if alarmZone.syncWithDomoSec then
zonesToSyncCheck = zonesToSyncCheck + 1
if zonesToSyncCheck > 1 then
domoticz.log('Configuration file error. Only a single zone can be set up to synchronize with the Domoticz\'s security panel.', domoticz.LOG_ERROR)
return
end
local newArmingMode = triggerInfo.trigger
if alarmZone.armingMode(domoticz) ~= newArmingMode then
domoticz.log('The Domoticz built in Security\'s arming mode changed to '..newArmingMode, domoticz.LOG_INFO)
domoticz.log('Syncing the new arming mode to zone '..alarmZone.name, domoticz.LOG_INFO)
if newArmingMode == domoticz.SECURITY_DISARMED then
alarmZone.disArmZone(domoticz)
else
alarmZone.armZone(domoticz, newArmingMode)
end
end
end
end
end
--- Checks how many open sensors there are in each zone.
-- Inserts the openSensorCount item into each alarmZone object
-- If defined, calls the ideAlarm custom helper function alarmOpenSensorsAllZones
-- @param domoticz The Domoticz object
-- @return Nil
local function countOpenSensors(domoticz)
for i, alarmZone in ipairs(alarmZones) do
local openSensorCount = 0
for sensorName, sensorConfig in pairs(alarmZone.sensors) do
local sensor = domoticz.devices(sensorName)
if sensor then
local includeSensor = (type(sensorConfig.enabled) == 'function') and sensorConfig.enabled(domoticz) or sensorConfig.enabled
if includeSensor and sensorConfig.nag and sensor.active then
openSensorCount = openSensorCount + 1
end
end
end
alarmZone.openSensorCount = openSensorCount
end
callIfDefined('alarmOpenSensorsAllZones')(domoticz, alarmZones)
end
--- Nags periodically about open sensors
-- @param domoticz The Domoticz object
-- @param triggerInfo The triggerInfo object
-- @return Nil
local function nagCheck(domoticz, device, triggerInfo)
-- You just came here to nag about open doors, didn't you?
local nagEventData = domoticz.data.nagEvent
local nagEventItem = nagEventData.getLatest()
if not nagEventItem then
nagEventData.add('dzVents rocks!')
nagEventItem = nagEventData.getLatest()
end
if not device then
-- Triggered by a timer event
-- First check if we have nagged recently.
local lastNagMinutesAgo = nagEventItem.time.minutesAgo
if lastNagMinutesAgo < ideAlarm.nagInterval() then
return
end
end
local zonesNagSensors = {}
local totalSensors = 0
for _, alarmZone in ipairs(alarmZones) do
local nagSensors = {}
for sensorName, sensorConfig in pairs(alarmZone.sensors) do
local sensor = domoticz.devices(sensorName)
if sensor then
local includeSensor = (type(sensorConfig.enabled) == 'function') and sensorConfig.enabled(domoticz) or sensorConfig.enabled
if includeSensor then
includeSensor = ((alarmZone.armingMode(domoticz) == domoticz.SECURITY_DISARMED)
or (alarmZone.armingMode(domoticz) == domoticz.SECURITY_ARMEDHOME and sensorConfig.class == SENSOR_CLASS_B))
end
local minutesAgo = sensor.lastUpdate.minutesAgo
if includeSensor and sensorConfig.nag
and sensor.active
and minutesAgo >= sensorConfig.nagTimeoutMins then
-- This sensor is worth nagging about
table.insert(nagSensors, sensor)
totalSensors = totalSensors + 1
end
end
end
table.insert(zonesNagSensors, nagSensors)
end
-- Exit if triggered by device and not all sections in all zones are closed/off
if totalSensors > 0 and device then return end
local hasNagged = false
for i, nagSensors in ipairs(zonesNagSensors) do
local lastValue = domoticz.data['nagZ'..tostring(i)]
if #nagSensors > 0 then hasNagged = true end
if (#nagSensors > 0) or (#nagSensors == 0 and lastValue > 0) then
callIfDefined('alarmNagOpenSensors')(domoticz, alarmZones[i], nagSensors, lastValue)
end
domoticz.data['nagZ'..tostring(i)] = #nagSensors
end
if hasNagged then
nagEventData.add('dzVents rocks!') -- Reset
end
end
local function onTimerTrigger(domoticz, triggerInfo)
nagCheck(domoticz, nil, triggerInfo)
end
function ideAlarm.execute(domoticz, device, triggerInfo)
local triggerType
-- What caused this script to trigger?
if triggerInfo.type == domoticz.EVENT_TYPE_DEVICE then
for _, alarmZone in ipairs(alarmZones) do
if device.deviceSubType == 'Text' then
if device.id == alarmZone.statusTextDevID then
triggerType = 'status' -- Alarm Zone Status change
break
elseif device.id == alarmZone.armingModeTextDevID then
triggerType = 'armingMode' -- Alarm Zone Arming Mode change
break
end
elseif device.active and (device.name == alarmZone.armAwayToggleBtn or device.name == alarmZone.armHomeToggleBtn) then
triggerType = 'toggleSwitch'
break
end
end
triggerType = triggerType or 'sensor'
elseif triggerInfo.type == domoticz.EVENT_TYPE_TIMER then
triggerType = 'timer'
elseif triggerInfo.type == domoticz.EVENT_TYPE_SECURITY then
triggerType = 'security'
end
domoticz.log('triggerType '.. triggerType, domoticz.LOG_INFO)
if triggerType == 'toggleSwitch' then
onToggleButton(domoticz, device)
return
elseif triggerType == 'status' then
onStatusChange(domoticz, device)
return
elseif triggerType == 'armingMode' then
onArmingModeChange(domoticz, device)
return
elseif triggerType == 'sensor' then
device.active = device.switchType ~= 'Door Lock' and device.active or device.state == 'Unlocked' and true or false -- Ugly hack!
if device.active then
onSensorChange(domoticz, device) -- Only Open or On states are of interest
else
nagCheck(domoticz, device) -- Only Closed or Off states are of interest
end
countOpenSensors(domoticz)
return
elseif triggerType == 'security' then
onSecurityChange(domoticz, triggerInfo)
elseif triggerType == 'timer' then
onTimerTrigger(domoticz, triggerInfo)
end
end
function ideAlarm.version()
return('ideAlarm V'..scriptVersion)
end
--- Lists all defined alarm zones and sensors
-- @param domoticz (Table). The domoticz table object.
-- @return (String) The listing string.
function ideAlarm.statusAll(domoticz)
local statusTxt = '\n\n'..ideAlarm.version()..'\nListing alarm zones and sensors:\n\n'
for i, alarmZone in ipairs(alarmZones) do
statusTxt = statusTxt..'Zone #'..tostring(i)..': '..alarmZone.name
..((alarmZone.mainZone) and ' (Main Zone) ' or '')
..((alarmZone.syncWithDomoSec) and ' (Sync with Domoticz\'s Security Panel) ' or '')
..', '..alarmZone.armingMode(domoticz)
..', '..alarmZone.status(domoticz)..'\n===========================================\n'
-- List all sensors for this zone
for sensorName, sensorConfig in pairs(alarmZone.sensors) do
local sensor = domoticz.devices(sensorName)
local isEnabled
if type(sensorConfig.enabled) == 'function' then
isEnabled = sensorConfig.enabled(domoticz)
else
isEnabled = sensorConfig.enabled
end
statusTxt = statusTxt..sensor.name
..(isEnabled and ': Enabled,' or ': Disabled,')
..(sensor.active and ' Tripped' or ' Not tripped')..'\n'
end
statusTxt = statusTxt..'\n'
end
return statusTxt
end
function ideAlarm.testAlert(domoticz)
if config.ALARM_TEST_MODE then
domoticz.log('Can not test alerts when ALARM_TEST_MODE is enabled in configuration file.' , domoticz.LOG_ERROR)
return false
end
local allAlertDevices = {}
for _, alarmZone in ipairs(alarmZones) do
for _, alertDevice in ipairs(alarmZone.alertDevices) do
allAlertDevices[alertDevice] = 'On'
end
end
local tempMessage = ideAlarm.statusAll(domoticz)
callIfDefined('alarmAlertMessage')(domoticz, tempMessage, config.ALARM_TEST_MODE)
domoticz.log(tempMessage, domoticz.LOG_FORCE)
for alertDevice, _ in pairs(allAlertDevices) do
domoticz.log(alertDevice, domoticz.LOG_FORCE)
domoticz.devices(alertDevice).switchOn().silent()
domoticz.devices(alertDevice).switchOff().afterSec(5).silent()
end
return true
end
--- Get the quantity of defined ideAlarm zones
-- @return Integer
function ideAlarm.qtyAlarmZones()
return(#alarmZones)
end
--- Get the timer triggers
-- @return table
function ideAlarm.timerTriggers()
local nagTriggerInterval = config.NAG_SCRIPT_TRIGGER_INTERVAL or {'every minute'}
return nagTriggerInterval
end
--- Get the logging level if defined in config file.
-- @return integer
function ideAlarm.loggingLevel(domoticz)
return (config.loggingLevel ~= nil and config.loggingLevel(domoticz) or nil)
end
--- Get the nag interval
-- @return integer
function ideAlarm.nagInterval()
return (config.NAG_INTERVAL_MINUTES or 6)
end
--- Get all devices that ideAlarm shall trigger upon
-- @return The trigger devices table
function ideAlarm.triggerDevices()
local tDevs = {}
for _, alarmZone in ipairs(alarmZones) do
if alarmZone.armAwayToggleBtn ~= '' then table.insert(tDevs, alarmZone.armAwayToggleBtn) end
if alarmZone.armHomeToggleBtn ~= '' then table.insert(tDevs, alarmZone.armHomeToggleBtn) end
table.insert(tDevs, alarmZone.statusTextDevID)
table.insert(tDevs, alarmZone.armingModeTextDevID)
-- We don't have a domoticz object at this stage. Otherwise we could check the arming mode and insert
-- only the trigger devices relevant to the alarm zones current arming mode
for sensorName, _ in pairs(alarmZone.sensors) do
table.insert(tDevs, sensorName)
end
end
return(tDevs)
end
return ideAlarm