Notifications
You must be signed in to change notification settings - Fork 0
/
ideAlarmConfig.lua
74 lines (63 loc) · 4.02 KB
/
ideAlarmConfig.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
--[[
Edit this file suit your needs
Place this file in the dzVents scripts folder using the name ideAlarmConfig.lua
See https://github.com/allan-gam/ideAlarm/wiki/configuration
After editing, always verify that it's valid LUA at http://codepad.org/ (Mark your paste as "Private"!!!)
--]]
local _C = {}
local SENSOR_CLASS_A = 'a' -- Sensor can be triggered in both arming modes. E.g. "Armed Home" and "Armed Away".
local SENSOR_CLASS_B = 'b' -- Sensor can be triggered in arming mode "Armed Away" only.
--[[
-------------------------------------------------------------------------------
DO NOT ALTER ANYTHING ABOVE THIS LINE
-------------------------------------------------------------------------------
--]]
_C.ALARM_TEST_MODE = false -- if ALARM_TEST_MODE is set to true it will prevent audible alarm
-- Interval for how often we shall trigger the script to check if nagging about open doors needs to be made
_C.NAG_SCRIPT_TRIGGER_INTERVAL = {'every other minute'} -- Format as defined by dzVents timers
-- Interval for how often we shall repeat nagging.
_C.NAG_INTERVAL_MINUTES = 6
-- Number of seconds which after the alert devices will be turned off
-- automatically even if an active alert situation still exists.
-- 0 = Disable automatic turning off alert devices.
_C.ALARM_ALERT_MAX_SECONDS = 30
-- Uncomment 3 lines below to override the default logging level
-- _C.loggingLevel = function(domoticz)
-- return domoticz.LOG_INFO -- Select one of LOG_DEBUG, LOG_INFO, LOG_ERROR, LOG_FORCE to override system log level
-- end
-- If You named your Domoticz Security Panel different from "Security Panel", uncomment the line below to specify the name.
-- _C.SECURITY_PANEL_NAME = 'Security Panel Fancy Name'
_C.ALARM_ZONES = {
-- Start configuration of the first alarm zone
{
name='Peellandhof',
armingModeTextDevID=153,
statusTextDevID=154,
entryDelay=30,
exitDelay=30,
alertDevices={124,127},
sensors = {
-- ['PIR01'] = {['class'] = SENSOR_CLASS_A, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = false, ['enabled'] = true},
-- ['PIR02'] = {['class'] = SENSOR_CLASS_A, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
-- ['PIR03'] = {['class'] = SENSOR_CLASS_A, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
-- ['PIR04'] = {['class'] = SENSOR_CLASS_B, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
-- ['WDW01'] = {['class'] = SENSOR_CLASS_A, ['nag'] = true, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
-- ['WDW02'] = {['class'] = SENSOR_CLASS_A, ['nag'] = true, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
-- ['WDW03'] = {['class'] = SENSOR_CLASS_A, ['nag'] = true, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
['Hal BG (PIR01)'] = {['class'] = SENSOR_CLASS_A, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = false, ['enabled'] = true},
['Woonkamer (PIR02)'] = {['class'] = SENSOR_CLASS_A, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
['Eettafel / keuken (PIR03)'] = {['class'] = SENSOR_CLASS_A, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
['Hal 1e (PIR04)'] = {['class'] = SENSOR_CLASS_B, ['nag'] = false, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
['Voordeur (WDW01)'] = {['class'] = SENSOR_CLASS_A, ['nag'] = true, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
['Tuindeuren (WDW02)'] = {['class'] = SENSOR_CLASS_A, ['nag'] = true, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true},
['Keukenraam (WDW03)'] = {['class'] = SENSOR_CLASS_A, ['nag'] = true, ['nagTimeoutMins'] = 5, ['armWarn'] = true, ['enabled'] = true}
},
armAwayToggleBtn='Toggle Z1 Arm Away',
armHomeToggleBtn='Toggle Z1 Arm Home',
mainZone = true,
canArmWithTrippedSensors = false,
syncWithDomoSec = true, -- Only a single zone is allowed to sync with Domoticz's built in Security Panel
},
-- End configuration of the first alarm zone
}