You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Copy of the issue opened by lathomas on the central repo: iihe-cms-sw#7
The list below is not ordered by priority :)
Some items are fairly fast, others will require some work.
All objects:
show trend vs integrated lumi (on top of runnb)
move the legend outside the plots
ask if we can get Cosmics into MINI and NANOAOD.
consider dynamic binning for response/resolution vs pt. (less bins at high pt).
save a few plots of response distributions for a few selected pt values (to check the Gaussian approximation). For example for muons 5<pt(offline)<10, 20<pt(offline)<25,100<pt(offline)<200
also monitor some HLT paths for electrons and muons (HLT_Ele32_WPTight_Gsf/HLT_IsoMu24/HLT_Mu50)
when unprescaled L1 bit "first bunch crossing in train" becomes available in NANOAOD, use it for prefiring studies
Muons
post/prefiring: write in the caption what the event selection is (unprefirable events or all events).
add L1 muons eta phi occupancy in bx0 all events.
Have a synchronization exercise with Yannis for prefiring.
Add a prefiring vs pt ? BMTF/OMTF/EMTF
Urgent fix bug in turn of L1Mu5 in OMTF. Seems there's a hard cut at L1mu>15 for OMTF/EMTF. (Probably better to propagate the offline muon to station 2.)
Add effcy vs eta, phi separately.
show L1Mu5/22(qual12) turnon for BMTF/OMTF/EMTF in the same plot
Extend pt range up to 1000 GeV (300-500-1000).
Response/resolution: Add plot for single quality
Add a specific effcy vs deltaR (for doublemuon, double electron).
Add displaced muon efficiency. (needs cosmics muon dataset in NANO)
Add charge measurement effcy vs eta and phi.
Electrons
extend the prefiring vs eta plot up to eta = 3. This implies a new event selection.
Add a plot of SingleEG30 prefirable with unprefirable events
Ask to have L1EG saved down to 5 GeV instead of 10 GeV in NANO.
Show L1EG15/30 turnon for non iso/loose iso/tight iso in same plot
adapt the range of y axis for resolution
Jets
Pre/postfiring zoom on the y axis.
Pre/postfiring: it seems to be really 0 (not a single event pre/postfiring), which seems surprising. Should be double checked.
save a few plots of ptbalance distributions for a few selected pt values. For example: 40/180
show L1Jet40/180 turnon for barrel/endcap/HF in the same plot.
Show pt balance vs photon pt.
Consider also using Z+jets to probe lower pt: show pt balance vs Z pt.
Response vs Pt has different y axis range for photon+jets and muon+jets
EtSum
Use EtSum stored instead of L1 bits to make turnons
Add zoom turnon for ETMHF
Show MET effcy vs Zpt for Z(mumu)+jets
Show MET effcy vs run nb for offlineMET(mu subtracted)>200.
Show the response defined as ETMHF/pt(Z) as a function of ptZ for Z(mumu)+jets.
Use different nvtx ranges.
The text was updated successfully, but these errors were encountered:
Copy of the issue opened by lathomas on the central repo:
iihe-cms-sw#7
The list below is not ordered by priority :)
Some items are fairly fast, others will require some work.
All objects:
Muons
Electrons
Jets
EtSum