forked from fieldtrip/fieldtrip
-
Notifications
You must be signed in to change notification settings - Fork 0
/
ft_electroderealign.m
734 lines (654 loc) · 31.7 KB
/
ft_electroderealign.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
function [elec_realigned] = ft_electroderealign(cfg, elec_original)
% FT_ELECTRODEREALIGN rotates, translates, scales and warps electrode positions. The
% default is to only rotate and translate, i.e. to do a rigid body transformation in
% which only the coordinate system is changed. With the right settings if can apply
% additional deformations to the input sensors (e.g. scale them to better fit the
% skin surface). The different methods are described in detail below.
%
% INTERACTIVE - You can display the skin surface together with the electrode or
% gradiometer positions, and manually (using the graphical user interface) adjust the
% rotation, translation and scaling parameters, so that the electrodes correspond
% with the skin.
%
% FIDUCIAL - You can apply a rigid body realignment based on three fiducial
% locations. After realigning, the fiducials in the input electrode set (typically
% nose, left and right ear) are along the same axes as the fiducials in the template
% electrode set.
%
% TEMPLATE - You can apply a spatial transformation/deformation that automatically
% minimizes the distance between the electrodes or gradiometers and a template or
% sensor array. The warping methods use a non-linear search to minimize the distance
% between the input sensor positions and the corresponding template sensors.
%
% HEADSHAPE - You can apply a spatial transformation/deformation that automatically
% minimizes the distance between the electrodes and the head surface. The warping
% methods use a non-linear search to minimize the distance between the input sensor
% positions and the projection of the electrodes on the head surface.
%
% PROJECT - This projects all electrodes to the nearest point on the
% head surface mesh.
%
% MOVEINWARD - This moves all electrodes inward according to their normals
%
% Use as
% [elec_realigned] = ft_electroderealign(cfg)
% with the electrode or gradiometer details in the configuration, or as
% [elec_realigned] = ft_electroderealign(cfg, elec_orig)
% with the electrode or gradiometer definition as 2nd input argument.
%
% The configuration can contain the following options
% cfg.method = string representing the method for aligning or placing the electrodes
% 'interactive' realign manually using a graphical user interface
% 'fiducial' realign using three fiducials (e.g. NAS, LPA and RPA)
% 'template' realign the electrodes to match a template set
% 'headshape' realign the electrodes to fit the head surface
% 'project' projects electrodes onto the head surface
% 'moveinward' moves electrodes inward along their normals
% cfg.warp = string describing the spatial transformation for the template and headshape methods
% 'rigidbody' apply a rigid-body warp (default)
% 'globalrescale' apply a rigid-body warp with global rescaling
% 'traditional' apply a rigid-body warp with individual axes rescaling
% 'nonlin1' apply a 1st order non-linear warp
% 'nonlin2' apply a 2nd order non-linear warp
% 'nonlin3' apply a 3rd order non-linear warp
% 'nonlin4' apply a 4th order non-linear warp
% 'nonlin5' apply a 5th order non-linear warp
% 'dykstra2012' back-project ECoG onto the cortex using energy minimzation
% 'hermes2010' back-project ECoG onto the cortex along the local norm vector
% 'fsaverage' surface-based realignment with FreeSurfer fsaverage brain (left->left or right->right)
% 'fsaverage_sym' surface-based realignment with FreeSurfer fsaverage_sym left hemisphere (left->left or right->left)
% 'fsinflated' surface-based realignment with FreeSurfer individual subject inflated brain (left->left or right->right)
% cfg.channel = Nx1 cell-array with selection of channels (default = 'all'),
% see FT_CHANNELSELECTION for details
% cfg.keepchannel = string, 'yes' or 'no' (default = 'no')
% cfg.fiducial = cell-array with the name of three fiducials used for
% realigning (default = {'nasion', 'lpa', 'rpa'})
% cfg.casesensitive = 'yes' or 'no', determines whether string comparisons
% between electrode labels are case sensitive (default = 'yes')
% cfg.feedback = 'yes' or 'no' (default = 'no')
%
% The electrode positions can be present in the 2nd input argument or can be specified as
% cfg.elec = structure with electrode positions or filename, see FT_READ_SENS
%
% If you want to realign the EEG electrodes using anatomical fiducials, you should
% specify the target location of the three fiducials, e.g.
% cfg.target.pos(1,:) = [110 0 0] % location of the nose
% cfg.target.pos(2,:) = [0 90 0] % location of the left ear
% cfg.target.pos(3,:) = [0 -90 0] % location of the right ear
% cfg.target.label = {'NAS', 'LPA', 'RPA'}
%
% If you want to align EEG electrodes to a single or multiple template electrode sets
% (which will be averaged), you should specify the template electrode sets either as
% electrode structures (i.e. when they are already read in memory) or their file
% names using
% cfg.target = single electrode set that serves as standard
% or
% cfg.target{1..N} = list of electrode sets that will be averaged
%
% If you want to align EEG electrodes to the head surface, you should specify the head surface as
% cfg.headshape = a filename containing headshape, a structure containing a
% single triangulated boundary, or a Nx3 matrix with surface
% points
%
% If you want to align ECoG electrodes to the pial surface, you first need to compute
% the cortex hull with FT_PREPARE_MESH. Then use either the algorithm described in
% Dykstra et al. (2012, Neuroimage) or in Hermes et al. (2010, J Neurosci methods) to
% snap the electrodes back to the cortical hull, e.g.
% cfg.method = 'headshape'
% cfg.warp = 'dykstra2012', or 'hermes2010'
% cfg.headshape = a filename containing headshape, a structure containing a
% single triangulated boundary, or a Nx3 matrix with surface
% points
% cfg.feedback = 'yes' or 'no' (default), feedback of the iteration procedure
%
% Additional configuration options for cfg.warp = 'dykstra2012'
% cfg.maxiter = number (default: 50), maximum number of optimization iterations
% cfg.pairmethod = 'pos' (default) or 'label', the method for electrode
% pairing on which the deformation energy is based
% cfg.isodistance = 'yes', 'no' (default) or number, to enforce isotropic
% inter-electrode distances (pairmethod 'label' only)
% cfg.deformweight = number (default: 1), weight of deformation relative
% to shift energy cost (lower increases grid flexibility)
%
% If you want to move the electrodes inward, you should specify
% cfg.moveinward = number, the distance that the electrode should be moved
% inward (negative numbers result in an outward move)
%
% If you want to align ECoG electrodes to the freesurfer average brain, you should
% specify the path to your headshape (e.g., lh.pial), and ensure you have the
% corresponding registration file (e.g., lh.sphere.reg) in the same directory.
% Moreover, the path to the local freesurfer home is required. Note that, because the
% electrodes are being aligned to the fsaverage brain, the corresponding brain should
% be also used when plotting the data, i.e. use freesurfer/subjects/fsaverage/surf/lh.pial
% rather than surface_pial_left.mat
% cfg.method = 'headshape'
% cfg.warp = 'fsaverage'
% cfg.headshape = string, filename containing subject headshape (e.g. <path to freesurfer/surf/lh.pial>)
% cfg.fshome = string, path to freesurfer
%
% See also FT_READ_SENS, FT_VOLUMEREALIGN, FT_INTERACTIVEREALIGN,
% FT_DETERMINE_COORDSYS, FT_PREPARE_MESH
% Copyright (C) 2005-2019, Robert Oostenveld, Arjen Stolk
%
% This file is part of FieldTrip, see http://www.fieldtriptoolbox.org
% for the documentation and details.
%
% FieldTrip is free software: you can redistribute it and/or modify
% it under the terms of the GNU General Public License as published by
% the Free Software Foundation, either version 3 of the License, or
% (at your option) any later version.
%
% FieldTrip is distributed in the hope that it will be useful,
% but WITHOUT ANY WARRANTY; without even the implied warranty of
% MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
% GNU General Public License for more details.
%
% You should have received a copy of the GNU General Public License
% along with FieldTrip. If not, see <http://www.gnu.org/licenses/>.
%
% $Id$
% the interactive method uses a global variable to get the data from the figure when it is closed
global norm
% these are used by the ft_preamble/ft_postamble function and scripts
ft_revision = '$Id$';
ft_nargin = nargin;
ft_nargout = nargout;
% do the general setup of the function
ft_defaults
ft_preamble init
ft_preamble debug
ft_preamble loadvar elec_original
ft_preamble provenance elec_original
ft_preamble trackconfig
% the ft_abort variable is set to true or false in ft_preamble_init
if ft_abort
return
end
% check if the input cfg is valid for this function
cfg = ft_checkconfig(cfg, 'forbidden', {'channels'}); % prevent accidental typos, see issue 1729
cfg = ft_checkconfig(cfg, 'forbidden', {'outline'});
cfg = ft_checkconfig(cfg, 'renamed', {'template', 'target'});
cfg = ft_checkconfig(cfg, 'renamedval', {'method', 'realignfiducials', 'fiducial'});
cfg = ft_checkconfig(cfg, 'renamedval', {'method', 'realignfiducial', 'fiducial'});
cfg = ft_checkconfig(cfg, 'renamedval', {'warp', 'homogenous', 'rigidbody'});
cfg = ft_checkconfig(cfg, 'renamedval', {'warp', 'homogeneous', 'rigidbody'});
% set the defaults
cfg.warp = ft_getopt(cfg, 'warp', 'rigidbody');
cfg.channel = ft_getopt(cfg, 'channel', 'all');
cfg.keepchannel = ft_getopt(cfg, 'keepchannel', 'no');
cfg.feedback = ft_getopt(cfg, 'feedback', 'no');
cfg.casesensitive = ft_getopt(cfg, 'casesensitive', 'no');
cfg.headshape = ft_getopt(cfg, 'headshape', []); % for triangulated head surface, without labels
cfg.target = ft_getopt(cfg, 'target', []); % for electrodes or fiducials, always with labels
cfg.coordsys = ft_getopt(cfg, 'coordsys'); % this allows for automatic template fiducial placement
if isempty(cfg.target)
% remove the field, otherwise ft_checkconfig will complain
cfg = rmfield(cfg, 'target');
end
if ~isempty(cfg.coordsys) && isempty(cfg.target)
% set the template fiducial locations according to the coordinate system
switch lower(cfg.coordsys)
case 'ctf'
cfg.target = [];
cfg.target.coordsys = 'ctf';
cfg.target.pos(1,:) = [100 0 0];
cfg.target.pos(2,:) = [0 80 0];
cfg.target.pos(3,:) = [0 -80 0];
cfg.target.label{1} = 'NAS';
cfg.target.label{2} = 'LPA';
cfg.target.label{3} = 'RPA';
otherwise
ft_error('the %s coordinate system is not automatically supported, please specify fiducial details in cfg.target')
end
end
% ensure that the right cfg options have been set corresponding to the method
switch cfg.method
case 'template' % realign the sensors to match a template set
cfg = ft_checkconfig(cfg, 'required', 'target', 'forbidden', 'headshape');
case 'headshape' % realign the sensors to fit the head surface
cfg = ft_checkconfig(cfg, 'required', 'headshape', 'forbidden', 'target');
case 'fiducial' % realign using the NAS, LPA and RPA fiducials
cfg = ft_checkconfig(cfg, 'required', 'target', 'forbidden', 'headshape');
case 'moveinward' % moves eletrodes inward
cfg = ft_checkconfig(cfg, 'required', 'moveinward');
end % switch cfg.method
if strcmp(cfg.method, 'fiducial') && isfield(cfg, 'warp') && ~isequal(cfg.warp, 'rigidbody')
ft_warning('The method ''fiducial'' implies a rigid body tramsformation. See also http://bugzilla.fieldtriptoolbox.org/show_bug.cgi?id=1722');
cfg.warp = 'rigidbody';
end
if isfield(cfg, 'headshape') && isa(cfg.headshape, 'config')
% convert the nested config-object back into a normal structure
cfg.headshape = struct(cfg.headshape);
end
if isfield(cfg, 'target') && isa(cfg.target, 'config')
% convert the nested config-object back into a normal structure
cfg.target = struct(cfg.target);
end
% the data can be passed as input arguments or can be read from disk
hasdata = exist('elec_original', 'var');
% get the electrode definition that should be warped
if ~hasdata
elec_original = ft_fetch_sens(cfg);
else
% the input electrodes were specified as second input argument
% or read from cfg.inputfile
end
% ensure that the units are specified
elec_original = ft_determine_units(elec_original);
% ensure up-to-date sensor description (Oct 2011)
elec_original = ft_datatype_sens(elec_original);
% ensure that channel and electrode positions are the same
assert(isequaln(elec_original.elecpos, elec_original.chanpos), 'this function requires same electrode and channel positions');
% remember the original electrode locations and labels and do all the work with a
% temporary copy, this involves channel selection and changing to lower case
elec = elec_original;
% instead of working with all sensors, only work with the fiducials
% this is useful for gradiometer structures
if strcmp(cfg.method, 'fiducial') && isfield(elec, 'fid')
fprintf('using the fiducials instead of the sensor positions\n');
elec.fid.unit = elec.unit;
elec = elec.fid;
end
usetarget = isfield(cfg, 'target') && ~isempty(cfg.target);
useheadshape = isfield(cfg, 'headshape') && ~isempty(cfg.headshape);
if usetarget
% get the template electrode definitions
if ~iscell(cfg.target)
cfg.target = {cfg.target};
end
Ntemplate = length(cfg.target);
for i=1:Ntemplate
if isstruct(cfg.target{i})
target(i) = cfg.target{i};
else
target(i) = ft_read_sens(cfg.target{i}, 'senstype', 'eeg');
end
end
clear tmp
for i=1:Ntemplate
% ensure up-to-date sensor description
% ensure that the units are consistent with the electrodes
tmp(i) = ft_convert_units(ft_datatype_sens(target(i)), elec.unit);
end
target = tmp;
end
if useheadshape
% get the surface describing the head shape
[headshape.pos, headshape.tri] = headsurface([], [], 'headshape', cfg.headshape);
% ensure that the units are consistent with the electrodes
headshape = ft_convert_units(headshape, elec.unit);
end
% convert all labels to lower case for string comparisons
cfg.channel = ft_channelselection(cfg.channel, elec.label);
if strcmp(cfg.casesensitive, 'no')
elec.label = lower(elec.label);
cfg.channel = lower(cfg.channel);
if usetarget
for j=1:length(target)
for i=1:length(target(j).label)
target(j).label{i} = lower(target(j).label{i});
end
end
end
end
[cfgsel, datsel] = match_str(cfg.channel, elec.label);
% keep the original channel labels
label_original = elec_original.label(datsel);
% start with an empty structure, this will be returned at the end
norm = [];
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
if strcmp(cfg.method, 'template')
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% determine electrode selection and overlapping subset for warping
cfg.channel = ft_channelselection(cfg.channel, elec.label);
for i=1:Ntemplate
cfg.channel = ft_channelselection(cfg.channel, target(i).label);
end
% make consistent subselection of electrodes
[cfgsel, datsel] = match_str(cfg.channel, elec.label);
elec.label = elec.label(datsel);
elec.elecpos = elec.elecpos(datsel,:);
for i=1:Ntemplate
[cfgsel, datsel] = match_str(cfg.channel, target(i).label);
target(i).label = target(i).label(datsel);
target(i).elecpos = target(i).elecpos(datsel,:);
end
% compute the average of the target electrode positions
average = ft_average_sens(target);
fprintf('warping electrodes to average template... '); % the newline comes later
[norm.elecpos, norm.m] = ft_warp_optim(elec.elecpos, average.elecpos, cfg.warp);
norm.label = elec.label;
dpre = mean(sqrt(sum((average.elecpos - elec.elecpos).^2, 2)));
dpost = mean(sqrt(sum((average.elecpos - norm.elecpos).^2, 2)));
fprintf('mean distance prior to warping %f, after warping %f\n', dpre, dpost);
if strcmp(cfg.feedback, 'yes')
% create an empty figure, continued below...
figure
axis equal
axis vis3d
hold on
xlabel('x')
ylabel('y')
zlabel('z')
% plot all electrodes before warping
ft_plot_sens(elec, 'r*');
% plot all electrodes after warping
ft_plot_sens(norm, 'm.', 'label', 'label');
% plot the template electrode locations
ft_plot_sens(average, 'b.');
% plot lines connecting the input and the realigned electrode locations with the template locations
my_line3(elec.elecpos, average.elecpos, 'color', 'r');
my_line3(norm.elecpos, average.elecpos, 'color', 'm');
end
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
elseif strcmp(cfg.method, 'headshape')
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% determine electrode selection and overlapping subset for warping
cfg.channel = ft_channelselection(cfg.channel, elec.label);
[cfgsel, datsel] = match_str(cfg.channel, elec.label);
elec.label = elec.label(datsel);
elec.elecpos = elec.elecpos(datsel,:);
norm.label = elec.label;
if strcmp(cfg.warp, 'dykstra2012')
norm.elecpos = warp_dykstra2012(cfg, elec, headshape);
elseif strcmp(cfg.warp, 'hermes2010')
norm.elecpos = warp_hermes2010(cfg, elec, headshape);
elseif strcmp(cfg.warp, 'fsaverage')
norm.elecpos = warp_fsaverage(cfg, elec);
elseif strcmp(cfg.warp, 'fsaverage_sym')
norm.elecpos = warp_fsaverage_sym(cfg, elec);
elseif strcmp(cfg.warp, 'fsinflated')
norm.elecpos = warp_fsinflated(cfg, elec);
else
fprintf('warping electrodes to skin surface... '); % the newline comes later
[norm.elecpos, norm.m] = ft_warp_optim(elec.elecpos, headshape, cfg.warp);
dpre = ft_warp_error([], elec.elecpos, headshape, cfg.warp);
dpost = ft_warp_error(norm.m, elec.elecpos, headshape, cfg.warp);
fprintf('mean distance prior to warping %f, after warping %f\n', dpre, dpost);
end
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
elseif strcmp(cfg.method, 'fiducial')
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% the fiducials have to be present in the electrodes and in the template set
label = intersect(lower(elec.label), lower(target.label));
if ~isfield(cfg, 'fiducial') || isempty(cfg.fiducial)
% try to determine the names of the fiducials automatically
option1 = {'nasion' 'left' 'right'};
option2 = {'nasion' 'lpa' 'rpa'};
option3 = {'nz' 'left' 'right'};
option4 = {'nz' 'lpa' 'rpa'};
option5 = {'nas' 'left' 'right'};
option6 = {'nas' 'lpa' 'rpa'};
if length(match_str(label, option1))==3
cfg.fiducial = option1;
elseif length(match_str(label, option2))==3
cfg.fiducial = option2;
elseif length(match_str(label, option3))==3
cfg.fiducial = option3;
elseif length(match_str(label, option4))==3
cfg.fiducial = option4;
elseif length(match_str(label, option5))==3
cfg.fiducial = option5;
elseif length(match_str(label, option6))==3
cfg.fiducial = option6;
else
ft_error('could not determine consistent fiducials in the input and the target, please specify cfg.fiducial or cfg.coordsys')
end
end
fprintf('matching fiducials {''%s'', ''%s'', ''%s''}\n', cfg.fiducial{1}, cfg.fiducial{2}, cfg.fiducial{3});
% determine electrode selection
cfg.channel = ft_channelselection(cfg.channel, elec.label);
[cfgsel, datsel] = match_str(cfg.channel, elec.label);
elec.label = elec.label(datsel);
elec.elecpos = elec.elecpos(datsel,:);
if length(cfg.fiducial)~=3
ft_error('you must specify exactly three fiducials');
end
% do case-insensitive search for fiducial locations
nas_indx = match_str(lower(elec.label), lower(cfg.fiducial{1}));
lpa_indx = match_str(lower(elec.label), lower(cfg.fiducial{2}));
rpa_indx = match_str(lower(elec.label), lower(cfg.fiducial{3}));
if length(nas_indx)~=1 || length(lpa_indx)~=1 || length(rpa_indx)~=1
ft_error('not all fiducials were found in the electrode set');
end
elec_nas = elec.elecpos(nas_indx,:);
elec_lpa = elec.elecpos(lpa_indx,:);
elec_rpa = elec.elecpos(rpa_indx,:);
% FIXME change the flow in the remainder
% if one or more template electrode sets are specified, then align to the average of those
% if no template is specified, then align so that the fiducials are along the axis
% find the matching fiducials in the template and average them
tmpl_nas = nan(Ntemplate,3);
tmpl_lpa = nan(Ntemplate,3);
tmpl_rpa = nan(Ntemplate,3);
for i=1:Ntemplate
nas_indx = match_str(lower(target(i).label), lower(cfg.fiducial{1}));
lpa_indx = match_str(lower(target(i).label), lower(cfg.fiducial{2}));
rpa_indx = match_str(lower(target(i).label), lower(cfg.fiducial{3}));
if length(nas_indx)~=1 || length(lpa_indx)~=1 || length(rpa_indx)~=1
ft_error('not all fiducials were found in template %d', i);
end
tmpl_nas(i,:) = target(i).elecpos(nas_indx,:);
tmpl_lpa(i,:) = target(i).elecpos(lpa_indx,:);
tmpl_rpa(i,:) = target(i).elecpos(rpa_indx,:);
end
tmpl_nas = mean(tmpl_nas,1);
tmpl_lpa = mean(tmpl_lpa,1);
tmpl_rpa = mean(tmpl_rpa,1);
% realign both to a common coordinate system
elec2common = ft_headcoordinates(elec_nas, elec_lpa, elec_rpa);
templ2common = ft_headcoordinates(tmpl_nas, tmpl_lpa, tmpl_rpa);
% compute the combined transform
norm = [];
norm.m = templ2common \ elec2common;
% apply the transformation to the fiducials as sanity check
norm.elecpos(1,:) = ft_warp_apply(norm.m, elec_nas, 'homogeneous');
norm.elecpos(2,:) = ft_warp_apply(norm.m, elec_lpa, 'homogeneous');
norm.elecpos(3,:) = ft_warp_apply(norm.m, elec_rpa, 'homogeneous');
norm.label = cfg.fiducial;
nas_indx = match_str(lower(elec.label), lower(cfg.fiducial{1}));
lpa_indx = match_str(lower(elec.label), lower(cfg.fiducial{2}));
rpa_indx = match_str(lower(elec.label), lower(cfg.fiducial{3}));
dpre = mean(sqrt(sum((elec.elecpos([nas_indx lpa_indx rpa_indx],:) - [tmpl_nas; tmpl_lpa; tmpl_rpa]).^2, 2)));
nas_indx = match_str(lower(norm.label), lower(cfg.fiducial{1}));
lpa_indx = match_str(lower(norm.label), lower(cfg.fiducial{2}));
rpa_indx = match_str(lower(norm.label), lower(cfg.fiducial{3}));
dpost = mean(sqrt(sum((norm.elecpos([nas_indx lpa_indx rpa_indx],:) - [tmpl_nas; tmpl_lpa; tmpl_rpa]).^2, 2)));
fprintf('mean distance between fiducials prior to realignment %f, after realignment %f\n', dpre, dpost);
if strcmp(cfg.feedback, 'yes')
% create an empty figure, continued below...
figure
axis equal
axis vis3d
hold on
xlabel('x')
ylabel('y')
zlabel('z')
% plot the first three electrodes before transformation
my_plot3(elec.elecpos(1,:), 'r*');
my_plot3(elec.elecpos(2,:), 'r*');
my_plot3(elec.elecpos(3,:), 'r*');
my_text3(elec.elecpos(1,:), elec.label{1}, 'color', 'r');
my_text3(elec.elecpos(2,:), elec.label{2}, 'color', 'r');
my_text3(elec.elecpos(3,:), elec.label{3}, 'color', 'r');
% plot the template fiducials
my_plot3(tmpl_nas, 'b*');
my_plot3(tmpl_lpa, 'b*');
my_plot3(tmpl_rpa, 'b*');
my_text3(tmpl_nas, ' nas', 'color', 'b');
my_text3(tmpl_lpa, ' lpa', 'color', 'b');
my_text3(tmpl_rpa, ' rpa', 'color', 'b');
% plot all electrodes after transformation
my_plot3(norm.elecpos, 'm.');
my_plot3(norm.elecpos(1,:), 'm*');
my_plot3(norm.elecpos(2,:), 'm*');
my_plot3(norm.elecpos(3,:), 'm*');
my_text3(norm.elecpos(1,:), norm.label{1}, 'color', 'm');
my_text3(norm.elecpos(2,:), norm.label{2}, 'color', 'm');
my_text3(norm.elecpos(3,:), norm.label{3}, 'color', 'm');
end
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
elseif strcmp(cfg.method, 'interactive')
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
tmpcfg = [];
tmpcfg.individual.elec = elec;
if isfield(cfg, 'headshape') && ~isempty(cfg.headshape)
tmpcfg.template.headshape = cfg.headshape;
end
if isfield(cfg, 'target') && ~isempty(cfg.target)
if iscell(cfg.target)
if numel(cfg.target)>1
ft_notice('computing the average electrode positions');
tmpcfg.template.elec = ft_average_sens(cfg.target);
else
tmpcfg.template.elec = cfg.target{1};
end
elseif isstruct(cfg.target)
tmpcfg.template.elec = cfg.target;
end
tmpcfg.template.elecstyle = {'facecolor', 'blue'};
ft_info('plotting the target electrodes in blue');
end
% use the more generic ft_interactiverealign for the actual work
tmpcfg = ft_interactiverealign(tmpcfg);
% only keep the transformation, it will be applied to the electrodes further down
norm.m = tmpcfg.m;
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
elseif strcmp(cfg.method, 'project')
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% determine electrode selection
cfg.channel = ft_channelselection(cfg.channel, elec.label);
[cfgsel, datsel] = match_str(cfg.channel, elec.label);
elec.label = elec.label(datsel);
elec.elecpos = elec.elecpos(datsel,:);
norm.label = elec.label;
[dum, norm.elecpos] = project_elec(elec.elecpos, headshape.pos, headshape.tri);
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
elseif strcmp(cfg.method, 'moveinward')
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% determine electrode selection
cfg.channel = ft_channelselection(cfg.channel, elec.label);
[cfgsel, datsel] = match_str(cfg.channel, elec.label);
elec.label = elec.label(datsel);
elec.elecpos = elec.elecpos(datsel,:);
norm.label = elec.label;
norm.elecpos = moveinward(elec.elecpos, cfg.moveinward);
else
ft_error('unknown method');
end % if method
% apply the spatial transformation to all electrodes, and replace the
% electrode labels by their case-sensitive original values
switch cfg.method
case {'template', 'headshape'}
if strcmpi(cfg.warp, 'dykstra2012') || strcmpi(cfg.warp, 'hermes2010') || ...
strcmpi(cfg.warp, 'fsaverage') || strcmpi(cfg.warp, 'fsaverage_sym') || strcmpi(cfg.warp, 'fsinflated')
elec_realigned = norm;
elec_realigned.label = label_original;
else
% the transformation is a linear or non-linear warp, i.e. a vector
try
% convert the vector with fitted parameters into a 4x4 homogenous transformation
% apply the transformation to the original complete set of sensors
elec_realigned = ft_transform_geometry(feval(cfg.warp, norm.m), elec_original);
catch
% the previous section will fail for nonlinear transformations
elec_realigned.label = label_original;
try
elec_realigned.elecpos = ft_warp_apply(norm.m, elec_original.elecpos, cfg.warp);
end % FIXME why is an error here not dealt with?
end
% remember the transformation
elec_realigned.(cfg.warp) = norm.m;
end
case {'fiducial' 'interactive'}
% the transformation is a 4x4 homogenous matrix
% apply the transformation to the original complete set of sensors
elec_realigned = ft_transform_geometry(norm.m, elec_original);
% remember the transformation
elec_realigned.homogeneous = norm.m;
case {'project', 'moveinward'}
% nothing to be done
elec_realigned = norm;
elec_realigned.label = label_original;
otherwise
ft_error('unknown method');
end
% the coordinate system is in general not defined after transformation
if isfield(elec_realigned, 'coordsys')
elec_realigned = rmfield(elec_realigned, 'coordsys');
end
% in some cases the coordinate system matches that of the input target or headshape
switch cfg.method
case 'template'
if isfield(target, 'coordsys')
elec_realigned.coordsys = target.coordsys;
end
case 'headshape'
if isfield(headshape, 'coordsys')
elec_realigned.coordsys = headshape.coordsys;
end
if isfield(elec_original, 'coordsys')
if strcmp(cfg.warp, 'dykstra2012') || strcmp(cfg.warp, 'hermes2010') % this warp simply moves the electrodes in the same coordinate space
elec_realigned.coordsys = elec_original.coordsys;
elseif strcmp(cfg.warp, 'fsaverage')
elec_realigned.coordsys = 'fsaverage';
elseif strcmp(cfg.warp, 'fsaverage_sym')
elec_realigned.coordsys = 'fsaverage_sym';
end
end
case 'fiducial'
if isfield(target, 'coordsys')
elec_realigned.coordsys = target.coordsys;
end
case 'interactive'
% the coordinate system is not known
case {'project', 'moveinward'}
% the coordinate system remains the same
if isfield(elec_original, 'coordsys')
elec_realigned.coordsys = elec_original.coordsys;
end
otherwise
ft_error('unknown method');
end
if istrue(cfg.keepchannel)
% append the channels that are not realigned
[dum, idx] = setdiff(elec_original.label, elec_realigned.label);
idx = sort(idx);
elec_realigned.label = [elec_realigned.label; elec_original.label(idx)];
elec_realigned.elecpos = [elec_realigned.elecpos; elec_original.elecpos(idx,:)];
end
% channel positions are identical to the electrode positions (this was checked at the start)
elec_realigned.chanpos = elec_realigned.elecpos;
elec_realigned.tra = eye(numel(elec_realigned.label));
% copy over unit, chantype, chanunit, and tra information in case this was not already done
if ~isfield(elec_realigned, 'unit') && isfield(elec_original, 'unit')
elec_realigned.unit = elec_original.unit;
end
if ~isfield(elec_realigned, 'chantype') && isfield(elec_original, 'chantype')
idx = match_str(elec_original.label, elec_realigned.label);
elec_realigned.chantype = elec_original.chantype(idx);
end
if ~isfield(elec_realigned, 'chanunit') && isfield(elec_original, 'chanunit')
elec_realigned.chanunit = elec_original.chanunit;
idx = match_str(elec_original.label, elec_realigned.label);
elec_realigned.chanunit = elec_original.chanunit(idx);
end
% update it to the latest version
elec_realigned = ft_datatype_sens(elec_realigned);
% do the general cleanup and bookkeeping at the end of the function
ft_postamble debug
ft_postamble trackconfig
ft_postamble previous elec_original
ft_postamble provenance elec_realigned
ft_postamble history elec_realigned
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% some simple SUBFUNCTIONs that facilitate 3D plotting
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
function h = my_plot3(xyz, varargin)
h = plot3(xyz(:,1), xyz(:,2), xyz(:,3), varargin{:});
function h = my_text3(xyz, varargin)
h = text(xyz(:,1), xyz(:,2), xyz(:,3), varargin{:});
function my_line3(xyzB, xyzE, varargin)
for i=1:size(xyzB,1)
line([xyzB(i,1) xyzE(i,1)], [xyzB(i,2) xyzE(i,2)], [xyzB(i,3) xyzE(i,3)], varargin{:})
end