moc32 commented Jul 29, 2024

Operating System

Others

Board

PIC0 RP2040

Firmware

examples/host_bare_api
ex_host_bare_api.zip

What happened ?

On pico rp2040 host, control endpoint get blocked after a random period of time. The status stage is missing and no more control_xfer is possible.

On a specific roline mouse, enumeration fails with wrong data toggle from the device. The USB_INTS_ERROR_DATA_SEQ_BITS is not handled in the current version of the sdk. The driver just panics.

How to reproduce ?

Compile the attached modified firmware and connect a keyboad. The scrolllock and capslock LED will blink (250ms). After a random period of time the blinking stops and the control endpoint is blocked.
For the data toggling issue, connect a roline mouse and enumeration will fail.

image

Debug Log as txt file (LOG/CFG_TUSB_DEBUG=2)

protocol=00, interface=00, report=00
[0:1] Class Request: 21 09 00 02 00 00 01 00
hw_endpoint_init dev 1 ep 0 out xfer 0
dev 1 ep 0 out setup buffer @ 0x50100180
endpoint control (0x50100100) <- 0xa0000180
Transfer complete
Sent setup packet
on EP 00 with 8 bytes
hcd_edpt_xfer dev_addr 1, ep_addr 0x0, len 1
Prepare BufCtrl: [0] = 0xf401 [1] = 0x0000
Buffer complete
buf_status 0x00000001
Single Buffered: ep_ctrl = A0000180
Sync BufCtrl: [0] = 0x6001 [1] = 0x0000
Short packet on buffer 0 with 1 bytes
Completed transfer of 1 bytes on ep 0 out
Transfer complete
on EP 00 with 1 bytes
[0:1] Control data:
0000: 00 |.|
hcd_edpt_xfer dev_addr 1, ep_addr 0x80, len 0
hw_endpoint_init dev 1 ep 0 in xfer 0
dev 1 ep 0 in setup buffer @ 0x50100180
endpoint control (0x50100100) <- 0xa0000180
Prepare BufCtrl: [0] = 0x7400 [1] = 0x0000
protocol=00, interface=00, report=06
Failed to set report
protocol=00, interface=00, report=00
Failed to set report
protocol=00, interface=00, report=06
Failed to set report
protocol=00, interface=00, report=00
Failed to set report
protocol=00, interface=00, report=06
Failed to set report
protocol=00, interface=00, report=00

Screenshots

image

Ellisys output on control endpoint transfer failure

I have checked existing issues, dicussion and documentation

  • I confirm I have checked existing issues, dicussion and documentation.
@moc32 moc32 added the Bug 🐞 label Jul 29, 2024
@moc32
Copy link
Author

moc32 commented Jul 29, 2024

@kilograham this might be an issue with the rp2040 usb host controller. TinyUSB host does not handle the wrong data toggle error but when I connect the same device to other host controllers including Windows, I don't get such an error.