You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
When duty cycling kicks in during AT+JOIN, the modem first responds with +ERR=-18 (as it should). On subsequent AT+JOIN attempts, still within the duty cycle quiet period, it responds with +ERR=-7. It does not seem to recover from +ERR=-7 once the quiet period has ended.
Steps to reproduce:
Repeatedly issue AT+JOIN in EU868 until you get +ERR=-18.
Wait for AT+BACKOFF to report 0
Issue AT+JOIN. This is most likely going to return +ERR=7.
The text was updated successfully, but these errors were encountered:
When duty cycling kicks in during AT+JOIN, the modem first responds with
+ERR=-18
(as it should). On subsequent AT+JOIN attempts, still within the duty cycle quiet period, it responds with+ERR=-7
. It does not seem to recover from+ERR=-7
once the quiet period has ended.Steps to reproduce:
AT+JOIN
in EU868 until you get+ERR=-18
.AT+BACKOFF
to report 0AT+JOIN
. This is most likely going to return+ERR=7
.The text was updated successfully, but these errors were encountered: