Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Attribute 0xff66/0x0227 and 0x0228 seems to be a Data Type Long octet string ( 0x43) instead of String ( 0x42) #82

Closed
pipiche38 opened this issue Aug 20, 2022 · 6 comments

Comments

@pipiche38
Copy link
Contributor

As describe in the title. It looks like 0300 is reported with data type 0x43 instead of 0x42

@pipiche38 pipiche38 changed the title Attribute 0xff66/0x0300 seems to be a Data Type Long octet string ( 0x43) instead of Char ( 0x42) Attribute 0xff66/0x0227 and 0x0228 seems to be a Data Type Long octet string ( 0x43) instead of String ( 0x42) Aug 20, 2022
@pipiche38
Copy link
Contributor Author

Attribute: 0003 ==> 0300
Status: 00
Data Type: 20 = Len = 1 byte
00

Attribute: 2702 ==> 0227
status: 00
DataType: 43 (Composite )
Len: 0000

Attriubute: 2802 => 0228
Status: 00
DataType: 43
Len: 0000

BTW, why is there no data ?

@fairecasoimeme
Copy link
Owner

0xFF66 / 0x0300 is an uint8 data type
0xff66 / 0x0227 is 0x43 data type --> Long String
0xff66 / 0x0228 is 0x43 data type --> Long String

I'll see why 0x0227 (PJOURF+1) give no datas (the linky is supposed to transmit by default some "NONUTILE" strings
For 0x0228 (PPOINTE), the Linky transmit nothing by default.

PJOURF+1 and PPOINTE value depend on EDF specific subscription. In the majority of cases, these values are not used

@pipiche38
Copy link
Contributor Author

my question was more , why 0x43 and not 0x42 , this makes the things quiet complexe as in your documentation you are only talking about string and you don't make the difference between Long String and string.
Long string is for string which are longer than 255 caracters

@fairecasoimeme
Copy link
Owner

because in the first study I didn't know how much character the Linky would send. Who can do more can do less.
As now I know I changed the type and I fix in v6

@pipiche38
Copy link
Contributor Author

v6 is not acceptable for me due to the routing table restriction.
So please provide eventually 2 firmwares one without routing table and one with routing table. This is not expected to reduce the routing table to 1 because some HUe users are generating issues

@fairecasoimeme
Copy link
Owner

this is the case but I need to finally the first version.
And your comment have no link with the issue

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests