Releases
v1.1
ewels
released this
18 Jul 08:17
New Modules:
BioBloom Tools
Create Bloom filters for a given reference and then to categorize sequences
Conpair
Concordance and contamination estimator for tumor–normal pairs
Disambiguate
Bargraph displaying the percentage of reads aligning to two different reference genomes.
Flexbar
Flexbar is a tool for flexible barcode and adapter removal.
HISAT2
New module for the HISAT2 aligner.
Made possible by updates to HISAT2 logging by @infphilo (requires --new-summary
HISAT2 flag).
HOMER
Support for summary statistics from the findPeaks
tool.
Jellyfish
Histograms to estimate library complexity and coverage from k-mer content.
Module written by @vezzi
MACS2
Summary of redundant rate from MACS2 peak calling.
QoRTs
QoRTs is toolkit for analysis, QC and data management of RNA-Seq datasets.
THetA2
THeTA2 (Tumor Heterogeneity Analysis) estimates tumour purity and clonal / subclonal copy number.
Module updates:
BCFtools
Option to collapse complementary changes in substitutions plot, useful for non-strand specific experiments (thanks to @vladsaveliev)
Bismark
M-Bias plots no longer show read 2 for single-end data.
Custom Content
New option to print raw HTML content to the report.
FastQ Screen
Fixed edge-case bug where many-sample plot broke if total number of reads was less than the subsample number.
Fixed incorrect logic of config option fastqscreen_simpleplot
(thanks to @daler )
Organisms now alphabetically sorted in fancy plot so that order is nonrandom (thanks to @daler )
Fixed bug where %No Hits
was missed in logs from recent versions of FastQ Screen.
HTSeq Counts
Fixed but so that module still works when --additional-attr
is specified in v0.8 HTSeq above (thanks to @nalcala )
Picard
CollectInsertSize: Fixed bug that could make the General Statistics Median Insert Size value incorrect.
Fixed error in sample name regex that left trailing ]
characters and was generally broken (thanks to @jyh1 for spotting this)
Preseq
Improved plots display (thanks to @vladsaveliev)
Qualimap
Only calculate bases over target coverage for values in General Statistics. Should give a speed increase for very high coverage datasets.
QUAST
Module is now compatible with runs from MetaQUAST (thanks to @vladsaveliev)
RSeQC
Changed default order of sections
Added config option to reorder and hide module report sections
New MultiQC features:
If a report already exists, execution is no longer halted.
_1
is appended to the filename, iterating if this also exists.
-f
/--force
still overwrites existing reports as before
Feature written by @Hammarn
New ability to run modules multiple times in a single report
Each run can be given different configuration options, including filters for input files
For example, have FastQC after trimming as well as FastQC before trimming.
See the relevant documentation for more instructions.
New option to customise the order of report sections
This is in addition / alternative to changing the order of module execution
Allows one module to have sections in multiple places (eg. Custom Content)
Tables have new column options floor
, ceiling
and minRange
.
Reports show warning if JavaScript is disabled
Config option custom_logo
now works with file paths relative to config file directory and cwd.
Bug Fixes:
Table headers now sort columns again after scrolling the table
Fixed buggy table header tooltips
Base clean_s_name
function now strips excess whitespace.
Line graphs don't smooth lines if not needed (number of points < maximum number allowed)
PDF output now respects custom output directory.
You can’t perform that action at this time.