Describe the bug

Kann man geschlossene Themen wieder öffnen? Ich habe jedenfalls nichts gefunden. Daher mache ich das Thema erneut auf.
Alle Details finden sich identisch unter #14418.

While Elli is working as expected in all modes and also MaxCurrent setting results in adjusted current, the MinCurrent setting is ignored and will always charge with 6A regardless of changed setting. This has been the case for many versions and I do not recall whether it has ever been working correctly. Today I tried once more with version 0.127.2 with the same result that any change to MinCurrent is ignored.

evcc-logs.zip

Steps to reproduce

Fresh start of EVCC with following steps and timestamp (trace logs are attached):

connect car with modus PV: 18:10:45
change mode to NOW: 18:11:30
change max current to 12A: 18:12:30 --> change successful
change max current to 16A: 18:13:45 --> change successful
change mode to MinPV: 18:14:30
change min current to 10A: 18:15:30 --> change ignored, stays on 6A
change min current to 8A: 18:16:30 --> change ignored, stays on 6A
change min current to 6A: 18:17:30
disconnect car: 18:18:00

Configuration details

# open evcc at http://evcc.local:7070
network:
  schema: http
  host: evcc.local # .local suffix announces the hostname on MDNS
  port: 7070

log: info
levels:
  cache: error
#  eebus: trace

# unique installation id
plant: xxx

interval: 10s # control cycle interval

meters:
- type: template
  template: sonnenbatterie 
  usage: grid  
  host: 192.168.189.38  
  port: 8080  
  name: grid1
- type: template
  template: sonnenbatterie 
  usage: pv  
  host: 192.168.189.38  
  port: 8080  
  name: pv2
- type: template
  template: sonnenbatterie 
  usage: battery  
  host: 192.168.189.38  
  port: 8080  
  name: battery3

chargers:
- type: template
  template: ellipro 
  ski: D9A2 03D9 E918 F950 EC97 E593 7251 E179 79A3 905E  
  ip: 192.168.189.34  
  name: wallbox5

loadpoints:
- title: Elli Wallbox
  charger: wallbox5
  mode: pv

site:
  title: Zu Hause
  residualPower: 100
  meters:
    grid: grid1
    pv:
    - pv2
    battery:
    - battery3

eebus:
  certificate:
      private: |
          -----BEGIN EC PRIVATE KEY-----
          xxx
          -----END EC PRIVATE KEY-----
      public: |
          -----BEGIN CERTIFICATE-----
          xxx
          -----END CERTIFICATE-----

Log details

Log can be found here because it is too long for this field: https://github.com/user-attachments/files/15859093/evcc-logs.zip

What type of operating system are you running?

Linux

Version

evcc version 0.127.2

@andig andig closed this as completed Jun 16, 2024