Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

version v3.4.0b8 : RC310 HC1 - missing summertemp ? #403

Closed
zibous opened this issue Mar 18, 2022 · 3 comments
Closed

version v3.4.0b8 : RC310 HC1 - missing summertemp ? #403

zibous opened this issue Mar 18, 2022 · 3 comments
Labels
bug Something isn't working

Comments

@zibous
Copy link

zibous commented Mar 18, 2022

Boiler GBx72/Trendline/Cerapur/Greenstar Si/27i   
Thermostat  RC300/RC310/Moduline 3000/1010H/CW400/Sense II

Version: EMS-ESP Version v3.4.0b8

Bug description
With version v3.4.0b8 I don't get the summertemp setting anymore.
Is this based on hc1 summer mode: off?

Version v3.3 shows:

"hc1": {
		"seltemp": 24,
		"temp": 24,
		"hatemp": 24,
		"hamode": "auto",
		"mode": "auto",
		"modetype": "comfort",
		"ecotemp": 15,
		"manualtemp": 24,
		"comforttemp": 25,
		"summertemp": 17,  <----- OK
		"designtemp": 45,
		"offsettemp": 0,
		"minflowtemp": 25,
		"maxflowtemp": 60,
		"roominfluence": 0,
		"curroominfl": 0,
		"nofrosttemp": 5,
		"targetflowtemp": 38,
		"heatingtype": "radiator",
		"summersetmode": "auto",
		"summermode": "off",
		"controlmode": "optimized",
		"program": "prog_1",
		"fastheatup": 0
	}

Device information

{
  "System": {
    "version": "3.4.0b8",
    "uptime": "002+05:57:31.665",
    "uptime (seconds)": 194251,
    "freemem": 149,
    "reset reason": "Software reset CPU / Software reset CPU",
    "temperature sensors": 0,
    "analog sensors": 0
  },
  "Network": {
    "connection": "WiFi",
    ...
  },
  "Status": {
    "bus status": "connected",
    "bus protocol": "Buderus",
    "bus telegrams received (rx)": 190341,
    "bus reads (tx)": 41887,
    "bus writes (tx)": 26,
    "bus incomplete telegrams": 16,
    "bus reads failed": 258,
    "bus writes failed": 0,
    "bus rx line quality": 100,
    "bus tx line quality": 100,
    "MQTT status": "connected",
    "MQTT publishes": 61997,
    "MQTT publish fails": 0,
    "temperature sensors": 0,
    "temperature sensor reads": 0,
    "temperature sensor fails": 0,
    "analog sensors": 0,
    "analog sensor reads": 0,
    "analog sensor fails": 0,
    "API calls": 0,
    "API fails": 0,
    "syslog started": true,
    "syslog level": "debug",
    "syslog ip": "10.1.1.96",
    "syslog queue": 1
  },
  "Devices": [
    {
      "type": "Boiler",
      "name": "GBx72/Trendline/Cerapur/Greenstar Si/27i",
      "device id": "0x08",
      "product id": 123,
      "version": "07.00",
      "entities": 66,
      "handlers received": "0x10 0x11 0x15 0x1C 0x18 0x19 0x1A 0x35 0x34 0x2A",
      "handlers fetched": "0x14 0x16 0x33 0x26",
      "handlers pending": "0xC2 0xD1 0xE3 0xE4 0xE5 0xE6 0xE9 0xEA"
    },
    {
      "type": "Thermostat",
      "name": "RC300/RC310/Moduline 3000/1010H/CW400/Sense II",
      "device id": "0x10",
      "product id": 158,
      "version": "74.02",
      "entities": 32,
      "handlers received": "0x06 0xA2 0x02BA 0x02BB 0x02BC 0x02BD 0x02BE 0x02BF 0x02C0 0x031D 0x0267",
      "handlers fetched": "0x02A5 0x02B9 0x029B 0x02F5 0x031B 0x023A 0x0240",
      "handlers pending": "0xA3 0x12 0x02AF 0x0471 0x02A6 0x02B0 0x029C 0x0472 0x02A7 0x02B1 0x029D 0x0473 0x02A8 0x02B2 0x029E 0x0474 0x02A9 0x02B3 0x029F 0x0475 0x02AA 0x02B4 0x02A0 0x0476 0x02AB 0x02B5 0x02A1 0x0477 0x02AC "
    },
    {
      "type": "Controller",
      "name": "BC25",
      "device id": "0x09",
      "product id": 125,
      "version": "03.05",
      "entities": 0
    }
  ]
}

Additional context

Boiler: Buderus GBx72/Trendline/Cerapur/Greenstar Si/27i (DeviceID:0x08, ProductID:123, Version:07.00) (66)
  heating active: off
  tapwater active: off
  selected flow temperature: 35.0 °C
  burner selected max power: 100 %
  heating pump modulation: 41 %
  outside temperature: 10.5 °C
  current flow temperature: 31.3 °C
  gas: off
  gas stage 2: off
  flame current: 0.0 uA
  heating pump: on
  fan: off
  ignition: off
  oil preheating: off
  heating activated: on
  heating temperature: 60.0 °C
  burner pump max power: 100 %
  burner pump min power: 10 %
  pump delay: 5
  burner min period: 10
  burner min power: 0 %
  burner max power: 100 %
  hysteresis on temperature: -6.0 °C
  hysteresis off temperature: 6.0 °C
  set flow temperature: 35.0 °C
  burner set power: 100 %
  burner current power: 0 %
  burner starts: 5279
  total burner operating time: 76 days 13 hours 44 minutes
  total heat operating time: 69 days 18 hours 46 minutes
  total UBA operating time: 281 days 12 hours 44 minutes
  last error code: 0Y(276) 24.11.2021 03:51 (0 min)
  service code: 0Y
  service code number: 204
  maintenance message: H00
  maintenance scheduled: date
  time to next maintenance: 6000 hours
  next maintenance date: 07.07.2023
  dhw set temperature: 57.0 °C
  dhw selected temperature: 57.0 °C
  dhw type: buffer
  dhw comfort: eco
  dhw flow temperature offset: 40.0 °C
  dhw max power: 100 %
  dhw circulation pump available: off
  dhw charging type: 3-way valve
  dhw hysteresis on temperature: -5.0 °C
  dhw hysteresis off temperature: 0.0 °C
  dhw disinfection temperature: 70.0 °C
  dhw circulation pump mode: 2x3min
  dhw circulation active: off
  dhw current intern temperature: 58.5 °C
  dhw current extern temperature: 58.5 °C
  dhw current tap water flow: 0.0 l/min
  dhw storage extern temperature: 58.5 °C
  dhw activated: on
  dhw one time charging: off
  dhw disinfecting: off
  dhw charging: off
  dhw recharging: off
  dhw temperature ok: on
  dhw active: off
  dhw 3way valve active: off
  dhw set pump power: 0 %
  dhw starts: 1087
  dhw active time: 6 days 18 hours 58 minutes

Thermostat: RC300/RC310/Moduline 3000/1010H/CW400/Sense II (DeviceID:0x10, ProductID:158, Version:74.02) (32)
  date/time: 19:20:18 18.03.2022
  floor drying: off
  damped outdoor temperature: 11.3 °C
  floor drying temperature: 0.0 °C
  building type: light
  minimal external temperature: -10.0 °C
  dhw set temperature: 60.0 °C
  dhw mode: own_prog
  dhw set low temperature: 45.0 °C
  dhw circulation pump mode: own_prog
  dhw charge duration: 60.0
  dhw charge: off
  dhw circuit 1 extra: 0.0 °C
  dhw disinfecting: on
  dhw disinfection day: we
  dhw disinfection time: 180.0
  hc1 selected room temperature: 24.0 °C
  hc1 : selTemp
  hc1 mode: auto
  hc1 mode type: comfort
  hc1 eco temperature: 20.0 °C
  hc1 manual temperature: 24.0 °C
  hc1 comfort temperature: 24.0 °C
  hc1 max flow temperature: 60.0 °C
  hc1 current room influence: 0.0 °C
  hc1 nofrost temperature: 0.0 °C
  hc1 target flow temperature: 35.0 °C
  hc1 heating type: radiator
  hc1 summer mode: off
  hc1 control mode: optimized
  hc1 program: prog_1
  hc1 temporary set temperature automode: 24.0 °C

Controller: BC25 (DeviceID:0x09, ProductID:125, Version:03.05) (0)
@zibous zibous added the bug Something isn't working label Mar 18, 2022
@MichaelDvP
Copy link
Contributor

Check Settings->Customization, there are some new values and the list is shifted after update.

But indeed there is a bug, the climate setting with empty fullname should not be displayed in console ( hc1 : selTemp).

@marc1de
Copy link

marc1de commented Mar 19, 2022

Please check if this value is disabled in "settings -> customisation"
In version v3.4.0b8 the numbering has changed.
image

(for a more detailed explanation by proddy or MichaelDvP see issue #396)

@zibous
Copy link
Author

zibous commented Mar 19, 2022

@marc1de
Thanks, found.

  1. Delete HA discovery
  2. Restart EMS

Bildschirmfoto 2022-03-19 um 11 58 49

Now i can see this in Homeassistant and on the dashboard.

{
  "datetime": "12:05:38 19.03.2022",
  "floordry": "off",
  "dampedoutdoortemp": 9.2,
  "floordrytemp": 0,
  "building": "light",
  "minexttemp": -10,
  "wwsettemp": 60,
  "wwmode": "own_prog",
  "wwsettemplow": 45,
  "wwcircmode": "own_prog",
  "wwchargeduration": 60,
  "wwcharge": "off",
  "wwextra1": 0,
  "wwdisinfecting": "on",
  "wwdisinfectday": "we",
  "wwdisinfecttime": 180,
  "hc1": {
    "seltemp": 24,
    "climate": "selTemp",
    "mode": "auto",
    "modetype": "comfort",
    "ecotemp": 20,
    "manualtemp": 24,
    "comforttemp": 24,
    "summertemp": 15,  <---- OK
    "designtemp": 45,
    "offsettemp": 0,
    "minflowtemp": 25,
    "maxflowtemp": 60,
    "roominfluence": 0,
    "roominflfactor": 4,
    "curroominfl": 0,
    "nofrosttemp": 0,
    "targetflowtemp": 37,
    "heatingtype": "radiator",
    "summersetmode": "auto",
    "summermode": "off",
    "controlmode": "optimized",
    "program": "prog_1",
    "tempautotemp": 24,
    "fastheatup": 0
  }
}

Thanks

@zibous zibous closed this as completed Mar 20, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working
Projects
None yet
Development

No branches or pull requests

3 participants