forked from rusefi/wideband
-
Notifications
You must be signed in to change notification settings - Fork 6
/
wideband-can.dbc
65 lines (53 loc) · 1.53 KB
/
wideband-can.dbc
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
VERSION ""
NS_ :
NS_DESC_
CM_
BA_DEF_
BA_
VAL_
CAT_DEF_
CAT_
FILTER
BA_DEF_DEF_
EV_DATA_
ENVVAR_DATA_
SGTYPE_
SGTYPE_VAL_
BA_DEF_SGTYPE_
BA_SGTYPE_
SIG_TYPE_REF_
VAL_TABLE_
SIG_GROUP_
SIG_VALTYPE_
SIGTYPE_VALTYPE_
BO_TX_BU_
BA_DEF_REL_
BA_REL_
BA_DEF_DEF_REL_
BU_SG_REL_
BU_EV_REL_
BU_BO_REL_
SG_MUL_VAL_
BS_:
BU_: WidebandController ECU
BO_ 400 WidebandStandardData: 8 WidebandController
SG_ Lambda : 16|16@1+ (0.0001,0) [0.5|2] "lambda" ECU
SG_ Version : 0|8@1+ (1,0) [0|0] "" ECU
SG_ Valid : 8|8@1+ (1,0) [0|1] "" ECU
SG_ TemperatureC : 32|16@1+ (1,0) [0|1000] "deg C" ECU
BO_ 401 WidebandDiagData: 8 WidebandController
SG_ Esr : 0|16@1+ (1,0) [0|10000] "ohms" ECU
SG_ NernstDc : 16|16@1+ (0.001,0) [0|1.5] "volt" ECU
SG_ PumpDuty : 32|8@1+ (0.392157,0) [0|100] "%" ECU
SG_ Status : 40|8@1+ (1,0) [0|0] "" ECU
SG_ HeaterDuty : 48|8@1+ (0.392157,0) [0|100] "%" ECU
BO_ 2398420992 WidebandControl: 2 ECU
SG_ BatteryVoltage : 0|8@1+ (0.1,0) [0|25] "volt" WidebandController
SG_ HeaterEnable : 8|8@1+ (1,0) [0|1] "" WidebandController
CM_ BO_ 400 "Increment ID by 2*N for the N-th controller";
CM_ SG_ 400 Version "Currently 0xA0";
CM_ SG_ 400 Valid "Set to 1 when the lambda value is valid";
CM_ BO_ 401 "Increment ID by 2*N for the N-th controller";
CM_ BO_ 2398420992 "Sent by ECU to control wideband controller";
CM_ SG_ 2398420992 BatteryVoltage "Provide system supply voltage for heater supply voltage compensation";
CM_ SG_ 2398420992 HeaterEnable "Set to 1 to allow sensor heating once engine runs";