read_raw_xdf() can I use the nominal sampling rate? #436
Comments
Hi @behinger! What a happy coincidence, I have just started working on refactoring (and improving) the XDF importer! I'm mentioning this because it is related to your question about nominal vs. effective sampling frequency. In summary, we decided to use the effective sampling frequency as the default, since currently we do not have any reason to believe that amplifier clocks are more accurate than computer clocks (see the original discussion for reference). Yes, this means that recordings will not be associated with "nice" frequencies like 1000 Hz, but you will see something like 1000.0001 Hz. In practice, this difference is absolutely negligible, so we (I) decided to use the effective sampling frequency as "the ground truth" in my implementation. One of the reasons why I chose the effective sampling frequency is that it is derived directly from the time stamps (by default, However, I can still see the value in wanting to treat the data as if it had been sampled with the nominal sampling frequency without any resampling/interpolation. I think we could handle this use case by maybe adding/changing a parameter, but I don't have a good idea yet. In addition, I don't know how we could handle gaps with this approach, which I think is pretty important. One option could be to let the user decide to explicitly disable any gap handling when treating the data as sampled with the nominal sampling frequency. Otherwise, I don't think there's a way around resampling/interpolation, as that's just how XDF works. I'm very open to input and ideas of course! |
thanks for the detailed response. I didnt remember I had posted on that other thread before.
-The gap issue: afaik the matlab importer has a gap detector, maybe this is used for this case? But if you do not resample, just modify the timestamps to follow the nominal rate, this shouldnt be a problem. sf_eff= 1001
sf_nom = 1000
t_lsl = range(0,step=1/sf_eff,length=100)
t_new = t_lsl ./sf_eff .* sf_nom edit: haha, this is indeed how I did it in Julia |
If done correctly, resampling should not introduce any weird artifacts. I'm trying to do it correctly this time 😄. Resampling is primarily necessary if there are multiple streams, yes, but as I've mentioned, I currently also use it even when there's only a single stream and I do not want the effective sampling frequency (but the nominal one for example). I don't know if pyxdf is able to detect gaps, but even if it does, I still need to create a regularly sampled 2D NumPy array, where gaps are filled with NaNs. As a workaround, you can do exactly what you suggest. I'm just not sure how to integrate this in the reader. If there are multiple streams, there is no way around interpolation/resampling, right? If there is only a single stream, there are two options: no resampling (which currently uses the effective sampling frequency) and resampling. I guess we could let the users decide whether to use the effective or the nominal sampling frequency in the first case. One idea to change the API would be to remove the WDYT? I have to ponder this a little more, maybe there is a better solution. |
(the resampling was via eeglab... never looked into it in detail, no time!)
|
Hi!
Thanks a ton for the xdf importer. I stumbled today because I want to use my EEG-Amp as the "main-clock", that is, change all timestamps to the nominal sampling rate provided by the EEG stream (I trust the amp more than my recording laptop). If I don't do this, every subject has a slightly different sampling rate (1000.0001 vs. 9999.9998 etc.), which is annoying to continue working with.
As I understood, I could specify a
fs_new
, but this would also resample my EEG-dataset; whereas I don't need resampling for that one, just dropping the timestamps and recacluating them with the nominal sampling rate (also sometimes we collect with differet FS, would be nice to just be able to specify the nominal one).I think this is the default behavior of the matlab xdf importer - but I dont have too much experience with that one either.
Maybe this is already possible, if not, I wonder how people are dealing with this issue right now? I'm willing to also spend some time to suggest a PR, but asking first is appropriate I think :)
Cheers, Bene
The text was updated successfully, but these errors were encountered: