The execd
plugin runs an external program as a long-running daemon. The
programs must output metrics in any one of the accepted Input Data Formats
on the process's STDOUT, and is expected to stay running. If you'd instead like
the process to collect metrics and then exit, check out the inputs.exec
plugin.
The signal
can be configured to send a signal the running daemon on each
collection interval. This is used for when you want to have Telegraf notify the
plugin when it's time to run collection. STDIN is recommended, which writes a
new line to the process's STDIN.
STDERR from the process will be relayed to Telegraf's logging facilities. By
default all messages on stderr
will be logged as errors. However, you can
log to other levels by prefixing your message with E!
for error, W!
for
warning, I!
for info, D!
for debugging and T!
for trace levels followed by
a space and the actual message. For example outputting I! A log message
will
create a info
log line in your Telegraf logging output.
This plugin is a service input. Normal plugins gather metrics determined by the interval setting. Service plugins start a service to listens and waits for metrics or events to occur. Service plugins have two key differences from normal plugins:
- The global or plugin specific
interval
setting may not apply - The CLI options of
--test
,--test-wait
, and--once
may not produce output for this plugin
In addition to the plugin-specific configuration settings, plugins support additional global and plugin configuration settings. These settings are used to modify metrics, tags, and field or create aliases and configure ordering, etc. See the CONFIGURATION.md for more details.
# Run executable as long-running input plugin
[[inputs.execd]]
## One program to run as daemon.
## NOTE: process and each argument should each be their own string
command = ["telegraf-smartctl", "-d", "/dev/sda"]
## Environment variables
## Array of "key=value" pairs to pass as environment variables
## e.g. "KEY=value", "USERNAME=John Doe",
## "LD_LIBRARY_PATH=/opt/custom/lib64:/usr/local/libs"
# environment = []
## Define how the process is signaled on each collection interval.
## Valid values are:
## "none" : Do not signal anything. (Recommended for service inputs)
## The process must output metrics by itself.
## "STDIN" : Send a newline on STDIN. (Recommended for gather inputs)
## "SIGHUP" : Send a HUP signal. Not available on Windows. (not recommended)
## "SIGUSR1" : Send a USR1 signal. Not available on Windows.
## "SIGUSR2" : Send a USR2 signal. Not available on Windows.
# signal = "none"
## Delay before the process is restarted after an unexpected termination
# restart_delay = "10s"
## Buffer size used to read from the command output stream
## Optional parameter. Default is 64 Kib, minimum is 16 bytes
# buffer_size = "64Kib"
## Disable automatic restart of the program and stop if the program exits
## with an error (i.e. non-zero error code)
# stop_on_error = false
## Data format to consume.
## Each data format has its own unique set of configuration options, read
## more about them here:
## https://github.com/influxdata/telegraf/blob/master/docs/DATA_FORMATS_INPUT.md
# data_format = "influx"
See the examples directory for basic examples in different languages expecting various signals from Telegraf:
- Go: Example expects
signal = "SIGHUP"
- Python: Example expects
signal = "none"
- Ruby: Example expects
signal = "none"
- shell: Example expects
signal = "STDIN"
Varies depending on the users data.
Varies depending on the users data.