KNXAutoResponder
This node will respond to read requests from the KNX BUS.
The node records all telegrams transmitted to the KNX BUS and store the values in memory.
It then responds to read requests by sending such memorized value back to the BUS as request.
If the group address to be read has no value yet, the node will respond with a default value.
The node will respond only to group addresses specified in the Respond to JSON field.
By default, there is a pre-compiled sample "Respond to" JSON text, where you can simply change/delete things. Please make sure not to use it as is!!!
Configuration
Property | Description |
---|---|
Gateway | Select the KNX gateway to be used |
Respond to | The node will respond to read requests coming from the group addresses specified in this JSON array. The format is specified below. |
JSON format
The JSON is always an array of object, containing each one directive. Each directive, tells to the node what do do.
Property | Description |
---|---|
note | Optional note key, for reminders. It will not be used anywhere. |
ga | The group address. You can also use the ".." wildchars, to specity a range of group addresses. The ".." can only be used with the third ga's level, ex: 1/1/0..257. See the samples below. |
dpt | The group address data point, in the format "1.001". It's optional if the ETS CSV file has been imported. |
default | The value sent to the BUS in response to a read request, when the group address value has not yet been memorized by the node. |
Let's start with one directive
The AutoResponder node will respond to read requests for the group address 2/7/1. If no value is yet in memory, it will reply with true.
The ETS CSV file must have been imported, otherwise you must add the "dpt":"1.001" key as well.
[
{
"ga": "2/7/1",
"default": true
}
]
A bit more complete directive
The AutoResponder node will respond to read requests for the group address starting from 3/1/1, to 3/1/22 included. If no value is yet in memory, it will reply with false.
There is also a note key, merely as a reminder note. It will not be used anywhere.
[
{
"note": "Virtual sensors coming from Hikvision AX-Pro",
"ga": "3/1/1..22",
"dpt": "1.001",
"default": false
}
]
Concatenating directives
The AutoResponder node will respond to read requests for the group address starting from 2/2/5, to 2/2/21 included. If no value is yet in memory, it will reply with a value of 25.
The AutoResponder node will also respond to read requests for the group address 2/4/22. If no value is yet in memory, it will reply with the string Unknown status!.
Please note the comma between each directive's JSON object.
[
{
"note": "DALI garden virtual brightness %",
"ga": "2/2/5..21"
"default": 25
},
{
"note": "Alarm armed status text",
"ga": "2/4/22",
"dpt": "16.001",
"default": "Unknown status!"
}
]
- OVERVIEW
- KNX DEVICE NODE (THE MOST USED)
- OTHER KNX NODES
- HUE NODES
-
SAMPLES
- Switch Light
- Dimming
- RGB color
- RGBW color + White
- Command a scene actuator
- Datapoint 213.x 4x Setpoint
- Datapoint 222.x 3x Setpoint
- Datapoint 237.x DALI diags
- Datapoint 2.x 1 bit proprity
- Datapoint 22.x RCHH Status
- Datetime to BUS
- Read Status
- Virtual Device
- Subtype decoded
- Alexa
- Apple Homekit
- Google Home
- Switch on/off POE port of Unifi switch
- Set configuration by msg
- Scene Controller node
- WatchDog node
- Logger node
- Global Context node
- Alerter node
- Load control node
- Viewer node
- Youtube samples