Dynamic metrics

To add a customized metric for measuring execution time cycles between two points. First extend and in IoT2Lib.h and IoT2Lib.c respectively.

/* BenchIoT/IoT2/IoT2-lib/IoT2Lib.h */

typedef volatile struct
{
    // Total runtime
    IoT2RuntimeCntr RuntimeCycles;
    // Core metrics
    IoT2MetricCntr ISRCycles;
    IoT2MetricCntr SVCCycles;
    IoT2MetricCntr PendSVCycles;
    IoT2MetricCntr SysTickCycles;
    IoT2MetricCntr IoT2Cycles;          
    // Security
    IoT2MetricCntr PrivCycles;
    IoT2MetricCntr PrivThreadCycles;
    IoT2MetricCntr UnprivCycles;
    // Performance 
    IoT2MetricCntr SleepCycles;
    IoT2MetricCntr DebugCycles;        // Additional counter for debugging
    // Add your customized metric below
    IoT2MetricCntr CustomMetric;

} IoT2CntrStruct;

};
/* BenchIoT/IoT2/IoT2-lib/IoT2Lib.c */
IoT2CntrStruct IoT2GlobalCounter = {
    // Total runtime
    .RuntimeCycles = {0},
    // Core metrics
    .ISRCycles = {0},
    .SVCCycles = {0},
    .PendSVCycles = {0},
    .SysTickCycles = {0},
    .InitCycles = {0},
    .IoT2Cycles = {0},
    // Security metrics
    .PrivCycles = {0},
    .PrivThreadCycles = {0},
    .UnprivCycles = {0},
    // Performance metrics
    .SleepCycles = {0},
    // extra counter for debugging
    .DebugCycles = {0},
    // Add the initialization to your custom metric below
    .CustomMetric = {0}
};

Then, you can use the following API to start the measurement

void iot2StartCustomeMetric(IoT2MetricCntr *metric)

To end the measurement,

void iot2EndCustomeMetric(IoT2MetricCntr *metric)

Now this will allow collecting the metric. The last step is to extend the result collector wrapper at (iot2ResultCollector.cpp). This allows sending the result through the serial port.

Note that you must add the following before the end_collector_msg

/* BenchIoT/IoT2/IoT2-mbed-wrappers/result_collection/iot2ResultCollector.cpp */
    //--------------------------------------------------------------------------
    // Your customized metric
    //--------------------------------------------------------------------------

    memset(result_buff, 0, sizeof(result_buff));

    if (snprintf(result_buff, sizeof(result_buff), 
        "CustomMetric cycles:%" PRIu32 "", 
        IoT2GlobalCounter.CustomMetric.metricCntr) < 0){

        // an error occured!
        result_collector.printf(
            "[-] ERROR: could not perform snprintf on CustomMetric cycles\r\n");
    }

    result_collector.printf("IoT2->%s\r\n", result_buff);


    //--------------------------------------------------------------------------
    //                   send end message to notify the result collector
    //--------------------------------------------------------------------------

For other dynamic metrics, this can be done by extending IoTLib files.

Static metrics

For static metrics, these can be added through python scripts at

BenchIoT/IoT2/IoT2_bench_drivers

Check iot2_measure_static_flash_and_ram.py for an example. You can also automate collecting your static metric at the end of iot2_run_experiments.py or iot2_run_benchmark.py.