Notifications
You must be signed in to change notification settings - Fork 361
Air Quality
Air Quality HomeKit Service.
Type | Service Type |
---|---|
15 | Air Quality |
Air Quality was introduced in firmware version 10.0 Kestrel
Status must be set using Service Notifications. There is not inputs available. To use specific hardware, Free Monitor Service supports many different data sources that can provide needed information to manage this service.
The following configuration is available:
Section | Key | Description |
---|---|---|
Actions |
"0" , "1" etc. |
The actions performed by the service |
Extra Data | "dt" |
Array to enable extra characteristics with more info |
Service Notifications | "m" |
Notifications sent from another service |
Initial Lock State | "ks" |
Lock state at boot |
Data History Characteristics |
Example:
{ "a" :
[
{ "t" : 15 }
]
}
Key | Action | Description |
---|---|---|
"0" | Unknown Status | The default action after boot |
"1" | Excellent | |
"2" | Good | |
"3" | Fair | |
"4" | Inferior | |
"5" | Poor |
Some extra characteristics can be added to this service:
Key | Description |
---|---|
1 |
Ozone Density |
2 |
Nitrogen Dioxide Density |
3 |
Sulphur Dioxide Density |
4 |
PM25 Density |
5 |
PM10 Density |
6 |
VOC Density |
It is possible to add some or all of them using "dt"
array.
To populate this information, Service Notifications or Free Monitors must be used.
Valid values are from 0
to 1000
.
Elements order in the declaration is important because Service Notifications and Data History Characteristics will use place number instead characteristic keys. For example, "dt" : [ 2, 4 ]
will add Nitrogen Dioxide Density and PM25 Density, but these characteristics will be 1
and 2
when use them in Service Notifications and Data History Characteristics.
The list of Service Notifications "m"
values supported are:
Key | Value | Notification |
---|---|---|
"v" | 0 | Unknown Status (default) |
1 | Excellent | |
2 | Good | |
3 | Fair | |
4 | Inferior | |
5 | Poor |
See the general Service Notifications section for details of how to configure these notifications.
The Initial Lock State about Service.
Key | Value | Notification |
---|---|---|
"ks" | 0 | Service locked |
1 | Service unlocked |
Characteristic | Description |
---|---|
0 | * Current State |
Home Accessory Architect
Home Accessory
Installation
Setup Mode
HAA Home Manager App
Configuration
About
General
| GPIOs Configuration
Accessory
| Actions
Service Types
Air Quality
Battery
Data History
Fan
Free Monitor
Garage Door
HAA iAirZoning
Heater Cooler
Humidifier
Light Sensor
Lightbulb
Lock Mechanism
Sensors
Power Measure
Security System
Stateless Button & Doorbell
Switch & Outlet
Temperature & Humidity
TV
Water Valve
Window Covering