AixLib v0.9.0
Pre-release
Pre-release
Non-backwards compatibility
We made a lot of changes for the Thermazone and Multizone models which broke the backward compatibility.
Release Notes
- Moisture calculation for the Thermal Zone models
- The ideal heater and cooler model was moved from Multi Zone to Thermal Zone model and was improved by the integration of outside temperature threshold values to prevent simultaneously heating and cooling
- Automatic calculation of water volumes and massflows for the Heatpump model
- The new Heatpump model from v0.7 is now also integrated for FastHVAC:
AixLib.FastHVAC.Components.HeatGenerators.HeatPump
- New modular CHP model for calibration:
AixLib.Fluid.BoilerCHP.ModularCHP
- New boiler model
AixLib.Fluid.BoilerCHP.BoilerNoControl
where the input is the part load rate - New pump model in package
AixLib.Fluid.Movers.PumpsPolynomialBased
that is based on polynomial functions - New heat exchanger model
AixLib.Fluid.HeatExchangers.DynamicHX
with dynamic behavior - New humidifier model
AixLib.Fluid.Humidifiers.GenericHumidifier_u
for steam and adiabatic humidification and part load rate as input - New air medium
AixLib.Media.AirIncompressible
with constant density for duct work simulations - Continuous Integration with regression tests to check simulation results
- Inclues latest IBPSA (15.01.2020)