When the MoonratII is power by a USB cable but connected to a 12V battery with a switch, switching the battery on and OFF does NOT change the output of the TMP36 voltage as measured by an oscilloscope on an Arduino R3.
However, using both a voltmeter and an oscilloscope, the 5V pin of the Arduino R3 voltage changes from 4.66 V to 4.99 volts. This has an immediate effect on the digitally measured temperatre, as evidenced by the screen shot below, which shows the voltage being switch off.
Note the ratios 4.99/4.66 and 166/156 are the same (1.070) to the third decimal place, confirming @ForrestErickson 's statement that the ADC converted measures a ratio.
We may futhermore conclude that this is only correct if the 5V voltage does not sag due to a load; however, when the system is powered at 12V, this is approximately correct.
Although this fragility is distressing, it may not matter if we power the incubator with a 12V power supply.
The text was updated successfully, but these errors were encountered:
While I assume you are using the R3 Arduino you should state so.
Please also state the exact firmware used.
Then, the first think I am going to do is look at the voltage on the reference to be set for 1.1V.
From the documentation
INTERNAL: a built-in reference, equal to 1.1 volts on the ATmega168 or ATmega328P and 2.56 volts on the ATmega32U4 and ATmega8 (not available on the Arduino Mega)
This will require a gain change for calculating the temperature.
When the MoonratII is power by a USB cable but connected to a 12V battery with a switch, switching the battery on and OFF does NOT change the output of the TMP36 voltage as measured by an oscilloscope on an Arduino R3.
However, using both a voltmeter and an oscilloscope, the 5V pin of the Arduino R3 voltage changes from 4.66 V to 4.99 volts. This has an immediate effect on the digitally measured temperatre, as evidenced by the screen shot below, which shows the voltage being switch off.
Note the ratios 4.99/4.66 and 166/156 are the same (1.070) to the third decimal place, confirming @ForrestErickson 's statement that the ADC converted measures a ratio.
We may futhermore conclude that this is only correct if the 5V voltage does not sag due to a load; however, when the system is powered at 12V, this is approximately correct.
Although this fragility is distressing, it may not matter if we power the incubator with a 12V power supply.