'Program to control soil moisture and temperature measurements for the stony soil lysimeters
Dim LCount
Public CS650(96,6)'96 CS650's each recording 6 variables (using the "M3!" command)
Public BattV
Public PTemp_C
DataTable (StonyLysimetersCS650,1,-1) 'DataTable(Name, TrigVar, Size) See page 128 of CR1000 manual for description
DataInterval (0,1,Min,2) 'DataInterval(TintoInt, Interval, Units, Lapses) See page 129 of CR1000 manual for description
Average(1,BattV,FP2,False)
Average(1,PTemp_C,FP2,False)
Sample (576,CS650(),IEEE4)
EndTable
BeginProg
SequentialMode
Scan (1,Min,0,0)
'Default Datalogger Battery Voltage measurement 'BattV'
Battery(BattV)
'Default Wiring Panel Temperature measurement 'PTemp_C'
PanelTemp(PTemp_C,_60Hz)
PortSet(4,1) 'Turn MUX1 and associated CS650's ON!!. Connect multiplexor reset and relay for 650's power to com port 4
Delay(0,3,Sec) 'Allow CS650's to warm up
LCount=1
SubScan(0,mSec,24)' SubScan(SubInterval, Units, Count) Count is the number no. of TDRs Leaving 650 mSec between each scan to allow SDI-12 function to excicute
PulsePort(8,10000) 'Switch to next AM16/32 channel. Connect multiplexor clock to Com port 8
SDI12Recorder (CS650(LCount,1),1,0,"M3!",1.0,0) 'SDI12Recorder(Dest, SDIPort, SDIAddress, SDICommand, Multiplier, Offset) All CS650's have an SDI address of 0 and all the sensor leads from MUXs are bused into C1
LCount=LCount+1
NextSubScan
PortSet(4,0) 'Turn MUX1 and associated CS650's OFF!!
Delay(0,150,mSec) 'Wait a bit between multiplexors
PortSet(5,1) 'Turn MUX2 and associated CS650's ON!!. Connect multiplexor reset and relay for 650's power to com port 5
Delay(0,3,Sec) 'Allow CS650's to warm up
SubScan(0,mSec,24)' SubScan(SubInterval, Units, Count) Count is the number no. of TDRs
PulsePort(8,10000) 'Switch to next AM16/32 channel. Connect multiplexor clock to Com port 8
SDI12Recorder (CS650(LCount,1),1,0,"M3!",1.0,0) 'SDI12Recorder(Dest, SDIPort, SDIAddress, SDICommand, Multiplier, Offset) All CS650's have an SDI address of 0 and all the sensor leads from MUXs are bused into C1
LCount=LCount+1
NextSubScan
PortSet(5,0) 'Turn MUX2 and associated CS650's OFF!!
Delay(0,150,mSec) 'Wait a bit between multiplexors
PortSet(6,1) 'Turn MUX3 and associated CS650's ON!!. Connect multiplexor reset and relay for 650's power to com port 6
Delay(0,3,Sec) 'Allow CS650's to warm up
SubScan(0,mSec,24)' SubScan(SubInterval, Units, Count) Count is the number no. of TDRs
PulsePort(8,10000) 'Switch to next AM16/32 channel. Connect multiplexor clock to Com port 8
SDI12Recorder (CS650(LCount,1),1,0,"M3!",1.0,0) 'SDI12Recorder(Dest, SDIPort, SDIAddress, SDICommand, Multiplier, Offset) All CS650's have an SDI address of 0 and all the sensor leads from MUXs are bused into C1
LCount=LCount+1
NextSubScan
PortSet(6,0) 'Turn MUX3 and associated CS650's OFF!!
Delay(0,150,mSec) 'Wait a bit between multiplexors
PortSet(7,1) 'Turn MUX4 and associated CS650's ON!!. Connect multiplexor reset and relay for 650's power to com port 7
Delay(0,3,Sec) 'Allow CS650's to warm up
SubScan(650,mSec,24)' SubScan(SubInterval, Units, Count) Count is the number no. of TDRs
PulsePort(8,10000) 'Switch to next AM16/32 channel. Connect multiplexor clock to Com port 8
SDI12Recorder (CS650(LCount,1),1,0,"M3!",1.0,0) 'SDI12Recorder(Dest, SDIPort, SDIAddress, SDICommand, Multiplier, Offset) All CS650's have an SDI address of 0 and all the sensor leads from MUXs are bused into C1
LCount=LCount+1
NextSubScan
PortSet(7,0) 'Turn MUX4 and associated CS650's OFF!!
Delay(0,150,mSec) 'Wait a bit before doing report
CallTable StonyLysimetersCS650 'Call Data Table
NextScan
EndProg