Select commit Hold shift + click to select a range
a6d0c1d
Establishing op model framework.
misi9170 Jan 19, 2024
5020252
First tests written; currently failing.
misi9170 Jan 19, 2024
a3a9eb4
Default behavior working.
misi9170 Jan 19, 2024
3118ce3
Rough model and tests.
misi9170 Jan 19, 2024
9907193
Slight improvement of docstring (still needs work).
misi9170 Jan 19, 2024
db6f97f
ruff.
misi9170 Jan 19, 2024
965680c
Add SimpleDeratingTurbine to TURBINE_MODEL_MAP
paulf81 Jan 19, 2024
19c20ba
start derating example
paulf81 Jan 20, 2024
b97c8d3
Add derated inputs
paulf81 Jan 20, 2024
2ad2c84
Add power_setpoints to calculate wake
paulf81 Jan 20, 2024
d389ae1
Merge branch 'v4' into v4-ms/derating-op-model
paulf81 Jan 25, 2024
841ce71
Merge branch 'v4' into v4-ms/derating-op-model
paulf81 Feb 3, 2024
a89bfb6
Remove pure formatting changes
paulf81 Feb 3, 2024
bb3f041
Remove pure formatting changes
paulf81 Feb 3, 2024
374a7e1
correct ti to array
paulf81 Feb 3, 2024
fd5c5b4
Add power_setpoints attribute and functions
paulf81 Feb 3, 2024
40abd9d
Call set_power_setpoints function
paulf81 Feb 3, 2024
77760e6
Initialize power_setpoints to a very large number
paulf81 Feb 3, 2024
0cc1dc8
Passes tests, new example still not running.
misi9170 Feb 5, 2024
bde76e7
power_setpoints, air_density propagated through turbine function calls.
misi9170 Feb 5, 2024
21671e4
Reg tests updated to new arguments.
misi9170 Feb 5, 2024
1e7e267
Update calls to thrust_coefficient() and axial_induction().
misi9170 Feb 5, 2024
09ffafc
Test example a bit more built out.
misi9170 Feb 5, 2024
4ef5089
Mixed model; single location for max power setpoint.
misi9170 Feb 5, 2024
79585e1
Ruff, isort.
misi9170 Feb 5, 2024
d015892
Test mixed model.
misi9170 Feb 5, 2024
44da1b0
Mixed model in example."
misi9170 Feb 5, 2024
12d388d
Allow mixed None and float values to be passed for power_setpoints.
misi9170 Feb 6, 2024
32b96f3
Remove temp code
paulf81 Feb 7, 2024
967bdc5
Propagating single default value.
misi9170 Feb 7, 2024
8e2d250
Minor cleanup.
misi9170 Feb 7, 2024
6aac1ef
Example improvements.
misi9170 Feb 7, 2024
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
116 changes: 116 additions & 0 deletions examples/40_test_derating.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,116 @@
# Copyright 2024 NREL

# Licensed under the Apache License, Version 2.0 (the "License"); you may not
# use this file except in compliance with the License. You may obtain a copy of
# the License at http://www.apache.org/licenses/LICENSE-2.0

# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations under
# the License.

# See https://floris.readthedocs.io for documentation

import matplotlib.pyplot as plt
import numpy as np
import yaml

from floris.tools import FlorisInterface


"""
Example to test out derating of turbines and mixed derating and yawing. Will be refined before
release. TODO: Demonstrate shutting off turbines also, once developed.
"""

# Grab model of FLORIS and update to deratable turbines
fi = FlorisInterface("inputs/gch.yaml")

with open(str(
fi.floris.as_dict()["farm"]["turbine_library_path"] /
(fi.floris.as_dict()["farm"]["turbine_type"][0] + ".yaml")
)) as t:
turbine_type = yaml.safe_load(t)
turbine_type["power_thrust_model"] = "simple-derating"

# Convert to a simple two turbine layout with derating turbines
fi.reinitialize(layout_x=[0, 1000.0], layout_y=[0.0, 0.0], turbine_type=[turbine_type])

# Set the wind directions and speeds to be constant over n_findex = N time steps
N = 50
fi.reinitialize(wind_directions=270 * np.ones(N), wind_speeds=10.0 * np.ones(N))
fi.calculate_wake()
turbine_powers_orig = fi.get_turbine_powers()

# Add derating
power_setpoints = np.tile(np.linspace(1, 6e6, N), 2).reshape(2, N).T
fi.calculate_wake(power_setpoints=power_setpoints)
turbine_powers_derated = fi.get_turbine_powers()

# Compute available power at downstream turbine
power_setpoints_2 = np.array([np.linspace(1, 6e6, N), np.full(N, None)]).T
fi.calculate_wake(power_setpoints=power_setpoints_2)
turbine_powers_avail_ds = fi.get_turbine_powers()[:,1]

# Plot the results
fig, ax = plt.subplots(1, 1)
ax.plot(power_setpoints[:, 0]/1000, turbine_powers_derated[:, 0]/1000, color="C0", label="Upstream")
ax.plot(
power_setpoints[:, 1]/1000,
turbine_powers_derated[:, 1]/1000,
color="C1",
label="Downstream"
)
ax.plot(
power_setpoints[:, 0]/1000,
turbine_powers_orig[:, 0]/1000,
color="C0",
linestyle="dotted",
label="Upstream available"
)
ax.plot(
power_setpoints[:, 1]/1000,
turbine_powers_avail_ds/1000,
color="C1",
linestyle="dotted", label="Downstream available"
)
ax.plot(
power_setpoints[:, 1]/1000,
np.ones(N)*np.max(turbine_type["power_thrust_table"]["power"]),
color="k",
linestyle="dashed",
label="Rated power"
)
ax.grid()
ax.legend()
ax.set_xlim([0, 6e3])
ax.set_xlabel("Power setpoint (kW)")
ax.set_ylabel("Power produced (kW)")

# Second example showing mixed model use.
turbine_type["power_thrust_model"] = "mixed"
yaw_angles = np.array([
[0.0, 0.0],
[0.0, 0.0],
[20.0, 10.0],
[0.0, 10.0],
[20.0, 0.0]
])
power_setpoints = np.array([
[None, None],
[2e6, 1e6],
[None, None],
[2e6, None,],
[None, 1e6]
])
fi.reinitialize(
wind_directions=270 * np.ones(len(yaw_angles)),
wind_speeds=10.0 * np.ones(len(yaw_angles)),
turbine_type=[turbine_type]*2
)
fi.calculate_wake(yaw_angles=yaw_angles, power_setpoints=power_setpoints)
turbine_powers = fi.get_turbine_powers()
print(turbine_powers)

plt.show()
13 changes: 13 additions & 0 deletions floris/simulation/farm.py
Original file line number Diff line number Diff line change
Expand Up @@ -32,6 +32,7 @@
Turbine,
)
from floris.simulation.rotor_velocity import compute_tilt_angles_for_floating_turbines_map
from floris.simulation.turbine.operation_models import POWER_SETPOINT_DEFAULT
from floris.type_dec import (
convert_to_path,
floris_array_converter,
Expand Down Expand Up @@ -92,6 +93,9 @@ class Farm(BaseClass):
tilt_angles: NDArrayFloat = field(init=False)
tilt_angles_sorted: NDArrayFloat = field(init=False)

power_setpoints: NDArrayFloat = field(init=False)
power_setpoints_sorted: NDArrayFloat = field(init=False)

hub_heights: NDArrayFloat = field(init=False)
hub_heights_sorted: NDArrayFloat = field(init=False, factory=list)

Expand Down Expand Up @@ -233,6 +237,11 @@ def initialize(self, sorted_indices):
sorted_indices[:, :, 0, 0],
axis=1,
)
self.power_setpoints_sorted = np.take_along_axis(
self.power_setpoints,
sorted_indices[:, :, 0, 0],
axis=1,
)
self.state = State.INITIALIZED

def construct_hub_heights(self):
Expand Down Expand Up @@ -341,6 +350,10 @@ def set_tilt_to_ref_tilt(self, n_findex: int):
* self.ref_tilts
)

def set_power_setpoints(self, n_findex: int):
self.power_setpoints = POWER_SETPOINT_DEFAULT * np.ones((n_findex, self.n_turbines))
self.power_setpoints_sorted = POWER_SETPOINT_DEFAULT * np.ones((n_findex, self.n_turbines))

def calculate_tilt_for_eff_velocities(self, rotor_effective_velocities):
tilt_angles = compute_tilt_angles_for_floating_turbines_map(
self.turbine_type_map_sorted,
Expand Down
1 change: 1 addition & 0 deletions floris/simulation/floris.py
Original file line number Diff line number Diff line change
Expand Up @@ -98,6 +98,7 @@ def __attrs_post_init__(self) -> None:
self.farm.construct_turbine_correct_cp_ct_for_tilt()
self.farm.set_yaw_angles(self.flow_field.n_findex)
self.farm.set_tilt_to_ref_tilt(self.flow_field.n_findex)
self.farm.set_power_setpoints(self.flow_field.n_findex)

if self.solver["type"] == "turbine_grid":
self.grid = TurbineGrid(
Expand Down
34 changes: 34 additions & 0 deletions floris/simulation/solver.py
Original file line number Diff line number Diff line change
Expand Up @@ -101,8 +101,10 @@ def sequential_solver(

ct_i = thrust_coefficient(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
thrust_coefficient_functions=farm.turbine_thrust_coefficient_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -118,8 +120,10 @@ def sequential_solver(
ct_i = ct_i[:, 0:1, None, None]
axial_induction_i = axial_induction(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
axial_induction_functions=farm.turbine_axial_induction_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand Down Expand Up @@ -330,8 +334,10 @@ def full_flow_sequential_solver(

ct_i = thrust_coefficient(
velocities=turbine_grid_flow_field.u_sorted,
air_density=turbine_grid_flow_field.air_density,
yaw_angles=turbine_grid_farm.yaw_angles_sorted,
tilt_angles=turbine_grid_farm.tilt_angles_sorted,
power_setpoints=turbine_grid_farm.power_setpoints_sorted,
thrust_coefficient_functions=turbine_grid_farm.turbine_thrust_coefficient_functions,
tilt_interps=turbine_grid_farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=turbine_grid_farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -344,8 +350,10 @@ def full_flow_sequential_solver(
ct_i = ct_i[:, 0:1, None, None]
axial_induction_i = axial_induction(
velocities=turbine_grid_flow_field.u_sorted,
air_density=turbine_grid_flow_field.air_density,
yaw_angles=turbine_grid_farm.yaw_angles_sorted,
tilt_angles=turbine_grid_farm.tilt_angles_sorted,
power_setpoints=turbine_grid_farm.power_setpoints_sorted,
axial_induction_functions=turbine_grid_farm.turbine_axial_induction_functions,
tilt_interps=turbine_grid_farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=turbine_grid_farm.correct_cp_ct_for_tilt_sorted,
Expand Down Expand Up @@ -495,8 +503,10 @@ def cc_solver(
turb_avg_vels = average_velocity(turb_inflow_field)
turb_Cts = thrust_coefficient(
turb_avg_vels,
flow_field.air_density,
farm.yaw_angles_sorted,
farm.tilt_angles_sorted,
farm.power_setpoints_sorted,
farm.turbine_thrust_coefficient_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -508,8 +518,10 @@ def cc_solver(
turb_Cts = turb_Cts[:, :, None, None]
turb_aIs = axial_induction(
turb_avg_vels,
flow_field.air_density,
farm.yaw_angles_sorted,
farm.tilt_angles_sorted,
farm.power_setpoints_sorted,
farm.turbine_axial_induction_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -526,8 +538,10 @@ def cc_solver(

axial_induction_i = axial_induction(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
axial_induction_functions=farm.turbine_axial_induction_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand Down Expand Up @@ -737,8 +751,10 @@ def full_flow_cc_solver(
turb_avg_vels = average_velocity(turbine_grid_flow_field.u_sorted)
turb_Cts = thrust_coefficient(
velocities=turb_avg_vels,
air_density=flow_field_grid.air_density,
yaw_angles=turbine_grid_farm.yaw_angles_sorted,
tilt_angles=turbine_grid_farm.tilt_angles_sorted,
power_setpoints=turbine_grid_farm.power_setpoints_sorted,
thrust_coefficient_functions=turbine_grid_farm.turbine_thrust_coefficient_functions,
tilt_interps=turbine_grid_farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=turbine_grid_farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -751,8 +767,10 @@ def full_flow_cc_solver(

axial_induction_i = axial_induction(
velocities=turbine_grid_flow_field.u_sorted,
air_density=turbine_grid_flow_field.air_density,
yaw_angles=turbine_grid_farm.yaw_angles_sorted,
tilt_angles=turbine_grid_farm.tilt_angles_sorted,
power_setpoints=turbine_grid_farm.power_setpoints_sorted,
axial_induction_functions=turbine_grid_farm.turbine_axial_induction_functions,
tilt_interps=turbine_grid_farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=turbine_grid_farm.correct_cp_ct_for_tilt_sorted,
Expand Down Expand Up @@ -891,8 +909,10 @@ def turbopark_solver(

Cts = thrust_coefficient(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
thrust_coefficient_functions=farm.turbine_thrust_coefficient_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -904,8 +924,10 @@ def turbopark_solver(

ct_i = thrust_coefficient(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
thrust_coefficient_functions=farm.turbine_thrust_coefficient_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -920,8 +942,10 @@ def turbopark_solver(
ct_i = ct_i[:, 0:1, None, None]
axial_induction_i = axial_induction(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
axial_induction_functions=farm.turbine_axial_induction_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand Down Expand Up @@ -978,8 +1002,10 @@ def turbopark_solver(
turbulence_intensity_ii = turbine_turbulence_intensity[:, ii:ii+1]
ct_ii = thrust_coefficient(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
thrust_coefficient_functions=farm.turbine_thrust_coefficient_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand Down Expand Up @@ -1174,8 +1200,10 @@ def empirical_gauss_solver(

ct_i = thrust_coefficient(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
thrust_coefficient_functions=farm.turbine_thrust_coefficient_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -1190,8 +1218,10 @@ def empirical_gauss_solver(
ct_i = ct_i[:, 0:1, None, None]
axial_induction_i = axial_induction(
velocities=flow_field.u_sorted,
air_density=flow_field.air_density,
yaw_angles=farm.yaw_angles_sorted,
tilt_angles=farm.tilt_angles_sorted,
power_setpoints=farm.power_setpoints_sorted,
axial_induction_functions=farm.turbine_axial_induction_functions,
tilt_interps=farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=farm.correct_cp_ct_for_tilt_sorted,
Expand Down Expand Up @@ -1375,8 +1405,10 @@ def full_flow_empirical_gauss_solver(

ct_i = thrust_coefficient(
velocities=turbine_grid_flow_field.u_sorted,
air_density=turbine_grid_flow_field.air_density,
yaw_angles=turbine_grid_farm.yaw_angles_sorted,
tilt_angles=turbine_grid_farm.tilt_angles_sorted,
power_setpoints=turbine_grid_farm.power_setpoints_sorted,
thrust_coefficient_functions=turbine_grid_farm.turbine_thrust_coefficient_functions,
tilt_interps=turbine_grid_farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=turbine_grid_farm.correct_cp_ct_for_tilt_sorted,
Expand All @@ -1389,8 +1421,10 @@ def full_flow_empirical_gauss_solver(
ct_i = ct_i[:, 0:1, None, None]
axial_induction_i = axial_induction(
velocities=turbine_grid_flow_field.u_sorted,
air_density=turbine_grid_flow_field.air_density,
yaw_angles=turbine_grid_farm.yaw_angles_sorted,
tilt_angles=turbine_grid_farm.tilt_angles_sorted,
power_setpoints=turbine_grid_farm.power_setpoints_sorted,
axial_induction_functions=turbine_grid_farm.turbine_axial_induction_functions,
tilt_interps=turbine_grid_farm.turbine_tilt_interps,
correct_cp_ct_for_tilt=turbine_grid_farm.correct_cp_ct_for_tilt_sorted,
Expand Down
2 changes: 2 additions & 0 deletions floris/simulation/turbine/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -14,5 +14,7 @@

from floris.simulation.turbine.operation_models import (
CosineLossTurbine,
MixedOperationTurbine,
SimpleDeratingTurbine,
SimpleTurbine,
)
Loading