ZoneHVAC:HybridUnitaryHVAC ERR object type output #8326
Changes from 10 commits
c299e9b
9ad786a
9c6f064
fe821f6
b688a55
d635741
3d8a04e
b8404b1
6f9efec
b6c822d
9caf7d9
7994f7b
0c13045
9ee3bd3
af97526
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -468,7 +468,7 @@ namespace HybridUnitaryAirConditioners { | |
using namespace DataIPShortCuts; // Data for field names, blank numerics | ||
using namespace DataLoopNode; | ||
using DataSizing::OARequirements; // to find DesignSpecification:OutdoorAir pointer | ||
std::string CurrentModuleObject; // Object type for getting and error messages | ||
std::string cCurrentModuleObject; // Object type for getting and error messages | ||
Array1D_string Alphas; // Alpha items for object | ||
Array1D<Real64> Numbers; // Numeric items for object | ||
Array1D_string cAlphaFields; // Alpha field names | ||
|
@@ -486,9 +486,9 @@ namespace HybridUnitaryAirConditioners { | |
|
||
// SUBROUTINE PARAMETER DEFINITIONS: | ||
static std::string const RoutineName("GetInputZoneHybridUnitaryAirConditioners: "); | ||
CurrentModuleObject = "ZoneHVAC:HybridUnitaryHVAC"; | ||
NumZoneHybridEvap = inputProcessor->getNumObjectsFound(CurrentModuleObject); | ||
inputProcessor->getObjectDefMaxArgs(CurrentModuleObject, NumFields, NumAlphas, NumNumbers); | ||
cCurrentModuleObject = "ZoneHVAC:HybridUnitaryHVAC"; | ||
NumZoneHybridEvap = inputProcessor->getNumObjectsFound(cCurrentModuleObject); | ||
inputProcessor->getObjectDefMaxArgs(cCurrentModuleObject, NumFields, NumAlphas, NumNumbers); | ||
int MaxNumbers = max(0, NumNumbers); // Maximum number of numeric fields in all objects | ||
int MaxAlphas = max(0, NumAlphas); // Maximum number of alpha fields in all objects | ||
Alphas.allocate(MaxAlphas); | ||
|
@@ -506,7 +506,7 @@ namespace HybridUnitaryAirConditioners { | |
|
||
for (UnitLoop = 1; UnitLoop <= NumZoneHybridEvap; ++UnitLoop) { | ||
inputProcessor->getObjectItem(state, | ||
CurrentModuleObject, | ||
cCurrentModuleObject, | ||
UnitLoop, | ||
Alphas, | ||
NumAlphas, | ||
|
@@ -521,7 +521,7 @@ namespace HybridUnitaryAirConditioners { | |
IsNotOK = false; | ||
IsBlank = false; | ||
UtilityRoutines::VerifyName( | ||
Alphas(1), ZoneHybridUnitaryAirConditioner, UnitLoop - 1, IsNotOK, IsBlank, CurrentModuleObject + " Name"); | ||
Alphas(1), ZoneHybridUnitaryAirConditioner, UnitLoop - 1, IsNotOK, IsBlank, cCurrentModuleObject + " Name"); | ||
|
||
// A1, \field Name | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).Name = Alphas(1); | ||
|
@@ -543,32 +543,40 @@ namespace HybridUnitaryAirConditioners { | |
} | ||
|
||
// A4, \field Minimum Supply Air Temperature Schedule Named | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMin_schedule_pointer = GetScheduleIndex(state, Alphas(4)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMin_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(4) + '=' + Alphas(4)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
ErrorsFound = true; | ||
if (!lAlphaBlanks(4)) { | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMin_schedule_pointer = GetScheduleIndex(state, Alphas(4)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMin_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(4) + '=' + Alphas(4)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
ErrorsFound = true; | ||
} | ||
} | ||
// A5, \field Maximum Supply Air Temperature Schedule Name | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMax_schedule_pointer = GetScheduleIndex(state, Alphas(5)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMax_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(5) + '=' + Alphas(5)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
ErrorsFound = true; | ||
if (!lAlphaBlanks(5)) { | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMax_schedule_pointer = GetScheduleIndex(state, Alphas(5)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).TsaMax_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(5) + '=' + Alphas(5)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Made a test file with bad inputs in a bunch of fields, and some of the error messages are still broken:
|
||
ErrorsFound = true; | ||
} | ||
} | ||
// A6, \field Minimum Supply Air Humidity Ratio Schedule Name | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMin_schedule_pointer = GetScheduleIndex(state, Alphas(6)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMin_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(6) + '=' + Alphas(6)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
ErrorsFound = true; | ||
if (!lAlphaBlanks(6)) { | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMin_schedule_pointer = GetScheduleIndex(state, Alphas(6)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMin_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(6) + '=' + Alphas(6)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
ErrorsFound = true; | ||
} | ||
} | ||
// A7, \field Maximum Supply Air Humidity Ratio Schedule Name | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMax_schedule_pointer = GetScheduleIndex(state, Alphas(7)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMax_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(7) + '=' + Alphas(7)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
ErrorsFound = true; | ||
if (!lAlphaBlanks(7)) { | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMax_schedule_pointer = GetScheduleIndex(state, Alphas(7)); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).RHsaMax_schedule_pointer == 0) { | ||
ShowSevereError("Invalid " + cAlphaFields(7) + '=' + Alphas(7)); | ||
ShowContinueError("Entered in " + cCurrentModuleObject + '=' + cAlphaArgs(1)); | ||
ErrorsFound = true; | ||
} | ||
} | ||
|
||
// A8, \field Method to Choose Value of Controlled Inputs | ||
|
@@ -578,21 +586,21 @@ namespace HybridUnitaryAirConditioners { | |
// A11, \field Supply Air Node Name | ||
// A12, \field Relief Node Name | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).InletNode = GetOnlySingleNode(state, | ||
Alphas(9), ErrorsFound, CurrentModuleObject, Alphas(1), NodeType_Air, NodeConnectionType_Inlet, 1, ObjectIsNotParent); | ||
Alphas(9), ErrorsFound, cCurrentModuleObject, Alphas(1), NodeType_Air, NodeConnectionType_Inlet, 1, ObjectIsNotParent); | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).SecondaryInletNode = GetOnlySingleNode(state, Alphas(10), | ||
ErrorsFound, | ||
CurrentModuleObject, | ||
cCurrentModuleObject, | ||
Alphas(1), | ||
NodeType_Air, | ||
NodeConnectionType_OutsideAirReference, | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. This is kind of nit-picky, but |
||
1, | ||
ObjectIsNotParent); | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).OutletNode = GetOnlySingleNode(state, | ||
Alphas(11), ErrorsFound, CurrentModuleObject, Alphas(1), NodeType_Air, NodeConnectionType_Outlet, 1, ObjectIsNotParent); | ||
Alphas(11), ErrorsFound, cCurrentModuleObject, Alphas(1), NodeType_Air, NodeConnectionType_Outlet, 1, ObjectIsNotParent); | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).SecondaryOutletNode = GetOnlySingleNode(state, | ||
Alphas(12), ErrorsFound, CurrentModuleObject, Alphas(1), NodeType_Air, NodeConnectionType_ReliefAir, 1, ObjectIsNotParent); | ||
TestCompSet(CurrentModuleObject, Alphas(1), Alphas(9), Alphas(11), "Hybrid Evap Air Zone Nodes"); | ||
TestCompSet(CurrentModuleObject, Alphas(1), Alphas(10), Alphas(12), "Hybrid Evap Air Zone Secondary Nodes"); | ||
Alphas(12), ErrorsFound, cCurrentModuleObject, Alphas(1), NodeType_Air, NodeConnectionType_ReliefAir, 1, ObjectIsNotParent); | ||
TestCompSet(cCurrentModuleObject, Alphas(1), Alphas(9), Alphas(11), "Hybrid Evap Air Zone Nodes"); | ||
TestCompSet(cCurrentModuleObject, Alphas(1), Alphas(10), Alphas(12), "Hybrid Evap Air Zone Secondary Nodes"); | ||
|
||
// N1, \field System Maximum Supply AirFlow Rate | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).SystemMaximumSupplyAirFlowRate = Numbers(1); | ||
|
@@ -643,13 +651,15 @@ namespace HybridUnitaryAirConditioners { | |
// A18, \field Objective Function Minimizes | ||
|
||
// A19, \ OA requirement pointer | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).OARequirementsPtr = UtilityRoutines::FindItemInList(Alphas(19), OARequirements); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).OARequirementsPtr == 0) { | ||
ShowSevereError(RoutineName + cCurrentModuleObject + "=\"" + Alphas(1) + " invalid data"); | ||
ShowContinueError("Invalid-not found" + cAlphaFieldNames(19) + "=\"" + Alphas(19) + "\"."); | ||
ErrorsFound = true; | ||
} else { | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).OutdoorAir = true; | ||
if (!lAlphaBlanks(19)) { | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).OARequirementsPtr = UtilityRoutines::FindItemInList(Alphas(19), OARequirements); | ||
if (ZoneHybridUnitaryAirConditioner(UnitLoop).OARequirementsPtr == 0) { | ||
ShowSevereError(RoutineName + cCurrentModuleObject + " = " + Alphas(1) + " invalid data"); | ||
ShowContinueError("Invalid-not found " + cAlphaFields(19) + "=\"" + Alphas(19) + "\"."); | ||
ErrorsFound = true; | ||
} else { | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).OutdoorAir = true; | ||
} | ||
} | ||
|
||
int FirstModeAlphaNumber = 20; | ||
|
@@ -673,7 +683,7 @@ namespace HybridUnitaryAirConditioners { | |
} | ||
} | ||
// add the ZoneHVAC:HybridUnitaryHVAC Scaled Maximum Supply Air Volume Flow Rate to the Component Sizing Report Summary | ||
BaseSizer::reportSizerOutput(CurrentModuleObject, | ||
BaseSizer::reportSizerOutput(cCurrentModuleObject, | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).Name, | ||
"Scaled Maximum Supply Air Volume Flow Rate [m3/s]", | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).ScaledSystemMaximumSupplyAirVolumeFlowRate); | ||
|
@@ -683,16 +693,16 @@ namespace HybridUnitaryAirConditioners { | |
// setup output variables | ||
for (UnitLoop = 1; UnitLoop <= NumZoneHybridEvap; ++UnitLoop) { | ||
|
||
SetUpCompSets(CurrentModuleObject, | ||
SetUpCompSets(cCurrentModuleObject, | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).Name, | ||
CurrentModuleObject, | ||
cCurrentModuleObject, | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).Name, | ||
NodeID(ZoneHybridUnitaryAirConditioner(UnitLoop).InletNode), | ||
NodeID(ZoneHybridUnitaryAirConditioner(UnitLoop).OutletNode)); | ||
|
||
SetUpCompSets(CurrentModuleObject, | ||
SetUpCompSets(cCurrentModuleObject, | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).Name, | ||
CurrentModuleObject, | ||
cCurrentModuleObject, | ||
ZoneHybridUnitaryAirConditioner(UnitLoop).Name, | ||
NodeID(ZoneHybridUnitaryAirConditioner(UnitLoop).SecondaryInletNode), | ||
NodeID(ZoneHybridUnitaryAirConditioner(UnitLoop).SecondaryOutletNode)); | ||
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
The IDD has this as a required field so I just removed the statement about leaving the field blank.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Good catch. But the code for this input is wrong. See comment below.