Notifications
You must be signed in to change notification settings - Fork 19.3k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Auto Bed Level bug #10575
Comments
Maybe same thing as in #10526 ? |
Yes, looks like same issue even using linear (not bilinear from that #10526). One point to remark is activating LINEAR ADVANCE the things looks like to be ok. |
This issue is caused by a twisted X gantry or some other physical factor messing with your probe readings. This issue is most common on CR-10 and similar machines. There are various adjustments you can try, such as adjusting belt tension, adjusting the rollers, and making sure that cables and bowden tubes have adequate slack. |
Duplicate of #7673 |
Duplicate of #5983 |
Duplicate of #9529 |
This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new issue for related bugs. |
Using Marlin bugfix-1.1.x and even bugfix-2.0.x, I saw this issue:
Linear BAL algorithm do something wrong: left side of the bed is lower then the right side, difficulting the bed adhesion.
When I enable LINEAR ADVANCE tag in the marlin, the linear BAL algorithm do the job with perfection.
The issue happen only with the linear advance is disabled.
The text was updated successfully, but these errors were encountered: