Notifications
You must be signed in to change notification settings - Fork 26
Compatibility
Yurii edited this page Jun 14, 2024
·
60 revisions
Boiler | Master Member ID | Required settings | Notes |
---|---|---|---|
Baxi ECO Nova | default | default | Pressure sensor not supported, modulation level not stable |
Baxi AMPERA | 4 | Modulation sync with heating = on | Pressure sensor not supported, only heating (DHW not tested) |
Baxi NUVOLA Duo-tec HT 16 | default | default | - |
Baxi LUNA-3 | default | default | - |
Baxi Duo-tec Compact 24 | default | default | - |
Baxi ECO Four 24 F | default | default | - |
Baxi LUNA-3 COMFORT | default | DHW present = on Duplicate DHW to CH2 = on |
- |
Baxi ECO Life 1.24 F | default | default | - |
Baxi ECO-4s | default | default | DHW flow rate not supported |
Baxi Eco 5 Compact | default | default | Pressure sensor not supported |
Boiler | Master Member ID | Required settings | Notes |
---|---|---|---|
Ferroli DOMIcompact C 24 Board: MF08FA |
211 | default | Pressure sensor not supported |
Ferroli Kalis 24C | default | default | - |
Ferroli Atlas D Unit 30 | default | default | - |
Ferroli Divatech D C24 | default | Summer/winter mode = on | Modulation level not supported |
Boiler | Master Member ID | Required settings | Notes |
---|---|---|---|
Remeha Calenta Ace 40C | default | default | - |
AEG GBA124 | default | default | Pressure sensor not supported |
Thermet Ecocondens Silver 35kW | default | default | Pressure sensor not supported |
ITALTHERM TIME MAX 30F | default | Summer/winter mode = on | Pressure sensor not supported |
Viessmann Vitodens 0-50w | default | default | - |
Radiant R2KA | default | Modulation sync with heating = off | Pressure sensor not supported DHW flow rate sensor not supported |
Intergas Kombi Kompakt | default | default | - |
Baltur Tesis 24 | default | default | - |
Navien NCB700 | default | default | - |
Nova Florida Delfis CTFS 24 | default | default | - |
Buderus U072 | default | default | - |
Bosch wbn 6000-24 | default | default | - |
Mizudo M24TH | default | default | - |
Rinnai M060SN | default | Get min/max temp from boiler = off | - |
De Dietrich PMC-M 24/28MI PLUS | 11 | Summer/winter mode = on Heating CH2 always enabled = off |
Pressure sensor not supported DHW flow rate sensor not supported Exhaust temp sensor not supported |
Board | Chip | Flash | Recommended GPIOs | Where buy |
---|---|---|---|---|
Wemos D1 mini | ESP-8266EX | 4MB | Status LED: 13 OT In: 4 OT Out: 5 OT RX LED: 15 Outdoor sensor: 12 Indoor sensor: 14 |
Aliexpress |
Wemos D1 mini pro | ESP-8266EX | 16MB | Status LED: 13 OT In: 4 OT Out: 5 OT RX LED: 15 Outdoor sensor: 12 Indoor sensor: 14 |
Aliexpress |
Wemos D1 mini lite | ESP-8285 | 1MB | Status LED: 13 OT In: 4 OT Out: 5 OT RX LED: 15 Outdoor sensor: 12 Indoor sensor: 14 |
Aliexpress |
NodeMCU V3 | ESP-8266 | 4MB | Status LED: 2 OT In: 13 OT Out: 15 OT RX LED: 16 Outdoor sensor: 12 Indoor sensor: 4 |
Aliexpress |
Wemos S2 mini | ESP32-S2FN4R2 | 4MB | Status LED: 11 OT In: 33 OT Out: 35 OT RX LED: 12 Outdoor sensor: 9 Indoor sensor: 7 |
Aliexpress |
Wemos S3 mini | ESP32-S3FH4R2 | 4MB | Status LED: 11 OT In: 35 OT Out: 36 OT RX LED: 10 Outdoor sensor: 13 Indoor sensor: 12 |
Aliexpress |
Wemos C3 mini | ESP32-C3FH4 | 4MB | Status LED: 4 OT In: 8 OT Out: 10 OT RX LED: 5 Outdoor sensor: 0 Indoor sensor: 1 |
Aliexpress |
Wemos D1 mini 32 | ESP32-? | 4MB | Status LED: 2 OT In: 21 OT Out: 22 OT RX LED: 19 Outdoor sensor: 12 Indoor sensor: 18 |
Aliexpress |
NodeMCU 32S | ESP32-? | 4MB | Status LED: 2 OT In: 16 OT Out: 4 OT RX LED: 19 Outdoor sensor: 15 Indoor sensor: 26 |
Aliexpress |
Sensor | Tested | Where buy |
---|---|---|
DS18B20 | Yes | Aliexpress |
DS1822 | No | ? |
DS1820 | No | ? |
MAX31820 | No | ? |
MAX31850 | No | ? |