attaching response in request.py #78
Comments
If you added a flag to |
Right...that's a good point. A wfdisc row will have the information to get the response from sensor/instrument, but if a user wants to use the calib and calper from the wfdisc table as opposed to the instrument table that would require recalling the wfdisc table. If we are going to build the responses completely separately and attach, then it would just make sense to build entire inventories and using the obspy attach_response() function...but that comes with it's own adjustments for the network section of the ids. Could also build a response_from_wfid() type function where the wfids from get_wfdisc_rows could be passed through...but that would require outputting the wfids separately since get_waveforms() calls get_wfdisc_rows() and to make it one smooth function would still require the sensor and instrument tables. That's why passing the wfdisc calib/calper info trace.stats variables is one option since then could just go from stream directly to sensor/instrument without have to recall the wfdisc table. |
FWIW The way I use these functions is I first use the get_wfdisc_rows to get, well, the wfdisc rows which i display in a table. Then someone selects which rows they want to download and I call get_waveforms with the info from the selected rows. There's probably a better way to do it, but it works for me. In that workflow, just passing something like "remove_response=True" into get_waveforms would be the more intuitive way to go about it. |
What do you pass through to get_waveforms? wfids? If that's the case it may be a little simpler as long as the sensor and instrument table are defined in the config file. |
Right now it looks like just station, start/end times. I could probably change it to wfids, that sounds like a better solution anyway. It would still need the start/end times? |
get_waveforms already accepts wfids, iirc. Not that I'm advocating. |
wfids would give me the start and endtimes of that particular segment, so that would be enough I think |
hmm, looking at the documentation, if you pass a wfid to get_waveforms, it returns the full wfdisc row waveform(s)... I don't think that's what I want, I just want the portion from the start/end times (ie trimmed). ...Come to think of it, I kinda remember that being the reason I didn't use wfids...
|
Wouldn't trimming the stream be an ObsPy one-liner? No ideal for long traces, I guess, but hopefully not a deal-breaker... |
unless the time span straddled one or more files? Maybe not too difficult, but passing a station with start and end times does it for me so why not just do that? It makes sense that get_waveforms would return a full wfdisc file when passed a wfid, so that shouldn't change I think. |
Maybe it just makes sense to do a stream to response type function? Ultimately, the trace stats have all of the same fields as a wfdisc row aka station, channel, starttime, endtime |
It's also reasonable to imagine tacking any other |
Working on this...what I realized today is that read_waveform() which is called by wfdisc2trace() already populates the calib from the wfdisc table in the header...if we also have it populate the calper, then everything I would need to compare and check against the sensor/instrument table would already be there and I wouldn't have to go back to wfdisc....but we would have to set a custom value for calper as that's not in the obspy header spec |
Adding a (couple) variables to pass attach_response = True through to get_wfdisc_rows would be the cleanest implementation. A wfdisc row will have all of the information to get a response correctly in 90-95% of cases. There may be some edge cases where things go sideways, but we can deal with that later. Would need to pass attach_response = True and which calib/calper to use, the variables in wfdisc or the nominal variables in instrument. I think, for the time being, we would make assumptions on final units (Meters/Pascals) on behalf of the user though we could pass an additional variable.
ping: @cnlg-lanl @jkmacc-LANL @jwebster-LANL
Thoughts?