Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

D435i Depth System Broken after Dynamic Calibration #10182

Closed
ridanlukita opened this issue Jan 23, 2022 · 3 comments
Closed

D435i Depth System Broken after Dynamic Calibration #10182

ridanlukita opened this issue Jan 23, 2022 · 3 comments

Comments

@ridanlukita
Copy link

Required Info
Camera Model D435i
Firmware Version 5.13.00.50
Operating System & Version Linux (Ubuntu 20.04 LTS)
Kernel Version (Linux Only) 5.11.0-43-generic
Platform PC
SDK Version 2.50
Language -
Segment others

Issue Description

After I do Dynamic Calibration (v2.11.1.0), depth reading broken to become like this
Screenshot from 2022-01-24 04-07-53

This is the first time I encountered like this, usually calibration just works normally.

I have done:

  • Hardware reset
  • Updating firmware to latest version
  • On-chip, focal length, tare calibration (all failed)
    Screenshot from 2022-01-24 04-16-42

When I try to use Dynamic Calibration again, the blue area always reappear and therefore I cannot pass the rectification phase.
Screenshot from 2022-01-24 04-03-29
Screenshot from 2022-01-24 04-03-54

Is there any suggestion to solve this problem?

@MartyG-RealSense
Copy link
Collaborator

MartyG-RealSense commented Jan 24, 2022

Hi @ridanlukita Do you see an improvement if you follow the steps below to reset the calibration to factory-new defaults, please?

  1. Enable the depth stream.

  2. Go to the More option in the Viewer and select the Calibration Data menu option.

image

  1. When the 'Camera Calibration' window pops up, left-click on the box labeled 'I know what I'm doing' in the bottom corner of the window. This unlocks the Restore Factory button, making it selectable. When 'Restore Factory is clicked, it will reset the calibration values of the camera to their factory-new defaults. You may see a blue flash as the values are reset - this is normal.

image

  1. Finally, left-click on the Write Table button to write the reset calibration values to the camera hardware's storage and automatically close the Camera Calibration window.

@ridanlukita
Copy link
Author

Now it has been back to normal! The more I learn about this device, the more I realized there's enormous amazing physics applied behind it! Thanks a lot! @MartyG-RealSense

@MartyG-RealSense
Copy link
Collaborator

You are very welcome, @ridanlukita - it's excellent news that your camera has been corrected. Thanks very much for the update. :)

This was referenced Jan 25, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment