@mawzthefinn
Yes, even a change is just as slow as described.
In my particular application I go from 2S volt which is about 7v down to 2volts.
And the change back and forth is very lazy and slow.
When I use FAS40ADV instead of the AIN2, the change of voltage is immediate!!! So that's how I am certain it is an issue with the AIN2
It's on TDR10 latest FW. I haven't tried to see if this AIN2 issue is present on other receivers.
Hello.
When you hook up some volts to AIN2 lets say 3V
Then when you disconnect the 3V in telemetry, it will wind down to 0V over about 1-2 seconds.
So
3V
2.5V
2V
1.5V
1V
1.5V
0.5V
0V after 1-2 seconds.
So it's slow to react to change in volts.