I check my voltage sensors with a lab grade power supply, so I don't need to leave as much fudge factor on my pack voltage warnings. Playing with some Xact servos and OCD compels me to see how well I can make the values match my pack sensor and reality.

I found that while using the offset line in 'Telemetry/SRV# volt' the offset offered in hundredths (0.01 increments)actually offsets the sensor at tenths (0.1 increments), so out by a factor of 10. Tiny bug.

Thank you!

@bsongis-frsky bsongis-frsky self-assigned this Nov 5, 2024
@bsongis-frsky bsongis-frsky added the bug Something isn't working label Nov 5, 2024
@bsongis-frsky bsongis-frsky added this to the 1.5.19 milestone Nov 5, 2024