Fiber Metadata


fiber_id

attributeID
fiber_id Required
Description Unique identifier for the physical fiber, with a maximum of 8 alphanumeric characters with no special characters (e.g., underscores, period, dash).
Required True
Type String
Style Alphanumeric
Units or options --
Example F001

cable_id

attributeID
cable_id Required
Description Unique identifier associates this fiber to a specific cable.
Required True
Type String
Style Alphanumeric
Units or options --
Example CA001

fiber_geometry

attributeID
fiber_geometry Required
Description Geometry of fiber.
Required True
Type String
Style Controlled vocabulary
Units or options [linear
Example linear

fiber_mode

attributeID
fiber_mode Required
Description Mode of fiber.
Required True
Type String
Style Controlled vocabulary
Units or options [single-mode
Example linear

fiber_refraction_index

attributeID
fiber_refraction_index Required
Description Refractive index of the fiber (unitless). Typical value for single mode fiber is 1.4681.
Required True
Type Float
Style na
Units or options -
Example 1.4681

fiber_winding_angle

attributeID
fiber_winding_angle Optional
Description If helical, this is the winding angle relative to the center of the cable.
Required False
Type Float
Style na
Units or options -
Example -

fiber_winding_angle_unit

attributeID
fiber_winding_angle_unit Optional
Description Unit of fiber winding angle
Required False
Type String
Style Controlled vocabulary
Units or options degree
Example -

fiber_start_location

attributeID
fiber_start_location Optional
Description The start distance along the fiber with respect to the interrogator, referred to as StartLocus in PRODML.
Required False
Type Float
Style na
Units or options -
Example -

fiber_start_location_unit

attributeID
fiber_start_location_unit Optional
Description Unit of fiber start location.
Required False
Type String
Style Controlled vocabulary
Units or options [meter
Example meter

fiber_start_location

attributeID
fiber_start_location Optional
Description The start distance along the fiber with respect to the interrogator, referred to as StartLocus in PRODML.
Required False
Type Float
Style na
Units or options -
Example -

fiber_start_location_unit

attributeID
fiber_start_location_unit Optional
Description Unit of fiber start location.
Required False
Type String
Style Controlled vocabulary
Units or options [meter
Example meter

fiber_end_location

attributeID
fiber_end_location Optional
Description The end location or distance along the fiber with respect to the interrogator.
Required False
Type Float
Style na
Units or options -
Example -

fiber_end_location_unit

attributeID
fiber_end_location_unit Optional
Description Unit of fiber end location.
Required False
Type String
Style Controlled vocabulary
Units or options [meter
Example meter

fiber_optical_length

attributeID
fiber_optical_length Optional
Description Total length of this fiber. Typically, it is the sum of fiber_start_location and fiber_end_location.
Required False
Type Float
Style na
Units or options -
Example 8400

fiber_optical_length_unit

attributeID
fiber_optical_length_unit Optional
Description Unit of fiber optical length.
Required False
Type String
Style Controlled vocabulary
Units or options [meter
Example meter

fiber_one_way_attenuation

attributeID
fiber_one_way_attenuation Optional
Description Power loss for one-way travel of a beam of light. Typical value for single mode fiber is 0.4.
Required False
Type Float
Style na
Units or options -
Example -

fiber_one_way_attenuation_unit

attributeID
fiber_one_way_attenuation_unit Optional
Description Unit of fiber optical length.
Required False
Type String
Style Controlled vocabulary
Units or options [decibels/meter
Example -

comment

attributeID
comment Optional
Description Additional comments.
Required False
Type String
Style Free form text
Units or options --
Example na