-- MAXDOP setting algorithm for SQL Server
-- Part of the SQL Server DBA Toolbox at https://github.com/DavidSchanzer/Sql-Server-DBA-Toolbox
-- This script uses another method to try to calculate an appropriate value for MAXDOP
-- From the comments at the bottom of https://dba.stackexchange.com/questions/36522/maxdop-setting-algorithm-for-sql-server:
SELECT [ServerName] = @@SERVERNAME,
[ComputerName] = SERVERPROPERTY('ComputerNamePhysicalNetBIOS'),
[LogicalCPUs],
hyperthread_ratio,
[PhysicalCPU],
[HTEnabled],
LogicalCPUPerNuma,
[NoOfNUMA],
[MaxDop_Recommended] = CONVERT( INT,
CASE
WHEN [MaxDop_RAW] > 10 THEN
10
ELSE
[MaxDop_RAW]
END
),
[MaxDop_Current] = sc.value,
[MaxDop_RAW],
[Number of Cores]
FROM
(
SELECT [LogicalCPUs],
hyperthread_ratio,
[PhysicalCPU],
[HTEnabled],
LogicalCPUPerNuma,
[NoOfNUMA],
[Number of Cores],
[MaxDop_RAW] = CASE
WHEN [NoOfNUMA] > 1
AND HTEnabled = 0 THEN
LogicalCPUPerNuma
WHEN [NoOfNUMA] > 1
AND HTEnabled = 1 THEN
CONVERT(
DECIMAL(9, 4),
[NoOfNUMA] / CONVERT(DECIMAL(9, 4), Res_MAXDOP.PhysicalCPU)
* CONVERT(DECIMAL(9, 4), 1)
)
WHEN HTEnabled = 0 THEN
Res_MAXDOP.LogicalCPUs
WHEN HTEnabled = 1 THEN
Res_MAXDOP.PhysicalCPU
END
FROM
(
SELECT [LogicalCPUs] = osi.cpu_count,
osi.hyperthread_ratio,
[PhysicalCPU] = osi.cpu_count / osi.hyperthread_ratio,
[HTEnabled] = CASE
WHEN osi.cpu_count > osi.hyperthread_ratio THEN
1
ELSE
0
END,
LogicalCPUPerNuma,
[NoOfNUMA],
[Number of Cores]
FROM
(
SELECT [NoOfNUMA] = COUNT(Res.parent_node_id),
[Number of Cores] = Res.LogicalCPUPerNuma / COUNT(Res.parent_node_id),
Res.LogicalCPUPerNuma
FROM
(
SELECT s.parent_node_id,
LogicalCPUPerNuma = COUNT(1)
FROM sys.dm_os_schedulers s
WHERE s.parent_node_id < 64
AND s.status = 'VISIBLE ONLINE'
GROUP BY s.parent_node_id
) Res
GROUP BY Res.LogicalCPUPerNuma
) Res_NUMA
CROSS APPLY sys.dm_os_sys_info osi
) Res_MAXDOP
) Res_Final
CROSS APPLY sys.sysconfigures sc
WHERE sc.comment = 'maximum degree of parallelism'