With your analysis point settings already defined, you can Left Click
anywhere on the currently loaded image to place an analysis point at that location.
Analysis points will be displayed in your selected colour
, along with their assigned id
value and selected label
.
You can Right Click
anywhere within an existing analysis point circle to remove the analysis point. If you have multiple analysis point stacked on top of one another, the last analysis point placed will be the analysis point at the top of the stack. Therefore, when using Right Click
on a stack of analysis point, the analysis point at the top of the stack will be removed first.
You can Left Click
on the id
value of an existing analysis point within the table data. Doing so will set all analysis point settings to the be the same as the settings of the selected and existing analysis point.
Data which is displayed within the table at the bottom of the window displays the list of analysis point currently on the image. This data includes the following:
id
- The id value assigned to the analysis point. This is automatically incremented when new analysis points are added.
label
- The label assigned to the analysis point. Either
RefMark
orSpot
.
- The label assigned to the analysis point. Either
x
- The x coordinate location of the analysis point on the image.
y
- The y coordinate location of the analysis point on the image.
diameter
- The diameter of the analysis point measured in
µm
.
- The diameter of the analysis point measured in
scale
- The scale of the analysis point measured in
Pixels per µm
.
- The scale of the analysis point measured in
colour
- The colour of the analysis point, represented in a Hex Colour Code.
sample_name
- The sample name assigned to the analysis point.
mount_name
- The mount name assigned to the analysis point.
material
- The material assigned to the analysis point.
notes
- Any notes assigned to the analysis point.
The following fields can be modified after placing an analysis point. To modify these values, Left Click
twice on the cell containing the value you would like to modify. Once you have inputted your new value, press Enter
to confirm the change.
label
sample_name
mount_name
material
notes
When creating a new analysis point, any current metadata field values and analysis point settings will be applied to that new analysis point. Therefore, analysis point metadata fields and settings should be selected before an analysis point is created.
To change a metadata field, Left Click
on the input box of the metadata field you would like to change and type in your value.
To change the label
, click on the drop-down menu next to Label
and select your label. A label
can be either RefMark
or Spot
.
Note: A label
value can be changed after analysis point creation. Simply Left Click
twice on the cell containing the value you would like to modify. Once you have inputted your new value, press Enter
to confirm the change.
To change the colour
, click on the colour box next to Colour
and use the colour picker to select a colour.
To change the diameter
, either use the up/down arrows next to the Diameter
input box, or type in your own value. It must be a whole number.
Note: The Diameter
is measured in µm
To set the scale, complete the following steps:
- Press the
Set Scale
button. A Set Scale window will then open. - The image on the main window will become slightly grey. This means you can now draw a line across the image. Start by clicking once to create the start of the line and clicking again to create the end of the line. Pressing the
Clear
button will remove any current lines. - Now you can change the estimated distance in microns. To do this, either use the up/down arrows next to the
Distance
input box, or type in your own value. It must be a whole number. - Pressing
OK
will confirm the newscale
and close the Set Scale window.
Note: The Scale
is measured in Pixels per µm
To avoid issues image navigation issues, it is recommended to tab into the image viewer before attempting to navigate it. To do this, simply place your mouse over the current image, and press the Middle Mouse Button
.
To enable Image Navigation, hold down the Ctrl
key.
Image Navigation mode will be automatically disabled when you stop holding the Ctrl
key.
Whilst Image Navigation is enabled, simply use the mouse scroll wheel. Scrolling down
will zoom out, whilst scrolling up
will zoom in.
Whilst Image Navigation is enabled, hold down Left Click
on the current image and move your mouse to pan the image.
OR
You can use the arrow keys to move across the image in the corresponding direction.
Clear all of the currently existing analysis points.
Reset the id
values of the currently existing analysis points. This will make the id
values increment sequentially, starting from 1
.
Reset the current analysis point settings to default.
sample_name
=None
mount_name
=None
material
=None
colour
=yellow
/#ffff00
diameter
=10
scale
=1.0
To access file functionality, press the File
button in the toolbar, located at the top left of the application.
Import an image into the application.
- Press the
Import Image
button. - Select an image file using the file picker.
Export the current image with the current analysis points added to it.
- Press the
Export Image
button. - Locate the directory you wish to export the image file to.
- Input the filename for the image file.
By default, the exported file will be a PNG
file. However, you can add your own file extension to the filename if you wish to create a different file type.
Import a CSV
file of previously exported TACtool analysis point data.
- Press the
Import TACtool CSV
button. - Select a
CSV
file using the file picker.
The selected CSV
must be a file of previously saved coordinates, i.e. a TACtool CSV format.
Export the current analysis point data to a TACtool CSV file.
- Press the
Export TACtool CSV
button. - Locate the directory you wish to export the
CSV
file to. - Input the filename for the
CSV
file.
By default, the exported file will be a CSV
file. However, you can add your own file extension to the filename if you wish to create a different file type, though this is not recommended.
Note: Upon export, the sample_name
and id
columns will be concatenated into a single column labelled Name
, using the character pattern _#
to join them.
A guide for importing the resulting CSV into the ESI laser control software can be found here.
Import and recoordinate a given SEM CSV file, using the current reference points in TACtool.
- Ensure you currently have 3 analysis points with the label
RefMark
placed in TACtool. - Press the
Import and Recoordinate SEM CSV
button. - Select an input
CSV
file by clicking on theSelect Input CSV
button and then use the file picker. - Press the
Import and Recoordinate
button. - The SEM points from the given CSV file will then be imported as Analysis Points and recoordinated based on the initially placed reference points.
Notes:
- Imported SEM points will retain their existing
Particle ID
values, as they will be used to assign the Analysis Pointid
values. - When SEM points are imported from a CSV file, it is assumed that the origin for their coordinates will be top right, but the origin in TACtool is top left. To account for this,
SEM
coordinates automatically have theirx
axis inverted according to the currently loaded image, thus making their effective origin top left. - When the SEM points are imported using this method, they will adopt any of the current Analysis Point settings applied in the TACtool window.
- If there are more than
3
analysis points with the labelRefMark
in TACtool, the recoordination process will only use the first3
reference points from the Analysis Points Table Data.