ITS Calib: compatibility with data produced with IB commissioning tools #10505

Merged
merged 1 commit into from
Jan 11, 2023
Merged

ITS Calib: compatibility with data produced with IB commissioning tools #10505

merged 1 commit into from
Jan 11, 2023

Conversation

iravasen
Copy link
Contributor

@iravasen iravasen commented Dec 20, 2022

This PR allows to process data on disk obtained with CRU_ITS -> IB commissioning tools (https://gitlab.cern.ch/alice-its-wp10-firmware/CRU_ITS/-/blob/production/software/py/ib_tools/README.md).

The main changes here are due to the different format of the calibration word which is generated with those tools and to the different number of injections per charge (25).

Flag --enable-cru-its allow to activate the processing of this data while the option --ninj allow to set the number of injections per charge point which is 50 by default.

@iravasen
Copy link
Contributor Author

Hi @shahor02, can I kindly ask you to merge this PR when you have 2s, please? Thanks a lot in advance.