Some quick measurements shows a correlation between the internal temperature ADC channel and output CV error. temp-adc branch demonstrates this.
A small lookup table with interpolation could compensate.
Also we could have a warning on the calibration page is the temperature changes over the course of calibration.
I did not see any variation of the input CV jack readings of a "cold" unit (just powered on at room temp ~25C) vs. a "warm" unit (been powered on inside a fully enclosed case for >20 minutes)
The text was updated successfully, but these errors were encountered:
Some quick measurements shows a correlation between the internal temperature ADC channel and output CV error.
temp-adc
branch demonstrates this.A small lookup table with interpolation could compensate.
Also we could have a warning on the calibration page is the temperature changes over the course of calibration.
I did not see any variation of the input CV jack readings of a "cold" unit (just powered on at room temp ~25C) vs. a "warm" unit (been powered on inside a fully enclosed case for >20 minutes)